Install the lower cover
Install the lower cover at least via
three attachment holes and suitable
screws to the wall.
TIP
As the space for cabling in the FIL1101 is lim-
ited, it can also be installed on a wall outlet one
gang box.
Connect the lines
Minimize the length of the lines
above the lower cover in order to
place the lines without any prob-
lems and to prevent clamping the
lines when snapping on the up-
per cover.
Loosen the screws of the con-
nection terminal and connect the
lines according to the labelling.
Note: Wires can be placed next to the printed
circuit board. .
Settings for 2-wire technique
Ex works, the FIL1101 is set for
3-wire technique (J1 placed on
the left contacts or enclosed in
accessories kit = not plugged
in).
For 2-wire technique, place
matching resistor J1 on both
contacts on the right!
TCS TürControlSysteme AG, TCS Hotline Germany:
FAX: +49 (0) 41 94/ 9 88 129 Mail: hotline@tcsag.de
6
Assembly and installation
lower cover
4 x attachment holes
Shown is matching resistor in 2-wire technique.
matching resistor
J1 in 2-wire
technique
space for
wires
up
No cable
gland!
connection terminal a b E P
(top down)
Subject to technical changes.
FIL1101 UK 1A
05/2013
cable gland
mi