Value Air Distribution Box (ADB), Mechanical
r
e
q
23 Passing the Wire Through the Filter Notch
Filter
q
e
Filter Notch
w
r
6. Slide out the filter to expose the filter notch.
7. Pass all of the available 115 VAC power supply wire
and 6-pin unit electrical cord through the filter notch
and through the second slot of the ADB.

7 .2 Securing the Unit

NOTICE: Overtightening could damage the
rooftop component's base pan or ceiling template. Not
enough torque will cause an inadequate roof seal, and
could cause a leak.
I
All models in this manual use a four bolt pattern to
secure the ADB kit.
This section describes how to secure the
rooftop component to the roof.
1. For units that fit within the 14.0 x 14.0 in.
(366 x 366 mm) ceiling opening, press the entire unit
up toward the basepan and into the ceiling opening.
EN
w
ADB Second Slot
115 VAC Power Supply Wire
and 6-pin Unit Electrical Cord
2. Use the following figures to determine the proper
mounting pattern and bolt location.
A
C
24 Mounting Bolt Pattern - All Models
q
w
25 Mounting Bolt Location - All Models
Ceiling Template
q
3. Start each mounting bolt by hand, through the
ceiling template and up into the rooftop component
base pan.
4. Tighten the mounting bolts to the correct torque
specifications.
– For the FreshJet, tighten all four mounting bolts
evenly at 22.2 in. lbs (2.5 N·m).
– For all other models, tighten all four mounting
bolts evenly within 40 to 50 in. lbs (4.7 to
5.6 N·m).
Installation
B
D
w
w
w
Mounting Bolt
w
19