3-4.

Error Code List

When warning, caution, or checking of operation is needed, the unit indicates a message on the LCD monitor, blinks
the TALLY LED, and beeps a warning.
When an error is detected, the error code is displayed on the LCD monitor and operation is stopped. Error codes are
displayed as E-xxxxx (x: number).
Error code
Description
E-15030
System error
E-17001  
The media ID data in the EEPROM is abnormal
E-17003
The display block does not start
E-17004
The media block does not start
E-17006
The display block startup processing is abnormal
E-17007
The media block startup processing is abnormal
E-17015
The media block is abnormal
E-17017
Media block internal error
E-4xxxx
If two or more errors occur simultaneously
The highest-priority error is displayed.
When an error with a higher priority has been cleared, the one with the next priority is displayed.
PMW-50
Service action
Repair the DPR-350 board or replace it.
Rewrite the media ID data in the EEPROM.
For details, contact your local Sony Sales Office/Serv-
ice Center.
Repair the DCP-60 board or replace it.
Repair the DPR-350 board or replace it.
Repair the DCP-60 board or replace it.
Repair the DPR-350 board or replace it.
Repair the DPR-350 board or replace it.
Repair the DPR-350 board or replace it.
3-11