Circuit Protection Parts; Circuit Protection Element; Replacing Fuses And Ic Links - Sony PMW-50 Service Manual

Portable memory recorder
Hide thumbs Also See for PMW-50:
Table of Contents

Advertisement

1-7.

Circuit Protection Parts

1-7-1.

Circuit Protection Element

This unit is equipped with positive-characteristic thermistors (power thermistors) as circuit protection elements.
The positive-characteristic thermistor limits the electric current flowing through the circuit as the internal resistance
increases when an excessive current flows or when the ambient temperature increases.
If the positive-characteristic thermistor works, turn off the main power of the unit and inspect the internal circuit of the
unit. After the cause of the fault is eliminated and the positive-characteristic thermistor is cooled down, turn on the main
power again. The unit works normally. It takes about one minute to cool down the positive-characteristic thermistor
after the main power is turned off.
Board name
Ref. No.
DCP-60
THP100
DPR-350
THP130
THP131
THP132
THP133
RE-298
THP100
RE-300
THP100
1-7-2.

Replacing Fuses and IC Links

WARNING
Fuses and IC links are essential parts for safe operation. Be sure to use the parts specified in this manual.
Replacing any fuse or IC link with an unspecified one may cause fire or electric shock.
CAUTION
Replacing any fuse or IC link is replaced while power is supplied to the unit may cause electric shock.
Before replacing any fuse or IC link, turn off the POWER switch and also disconnect the battery pack and
the cable from the DC IN connector.
This unit is equipped with fuses and IC links. The fuses and IC links blow if overcurrent flows in the unit due to an
abnormality, In that case, turn off the power of the unit, inspect inside of the unit, and then remove the cause of the
overcurrent. After that, replace the defective parts.
Board name
Ref.No.
IF-1188
PS100
PS101
RE-299
F100
PMW-50
Address
Part No.
A1 (Side B)
1-771-845-21
A2 (Side A)
1-805-726-11
A2 (Side A)
1-805-726-11
A3 (Side A)
1-805-726-11
A3 (Side A)
1-805-726-11
B2 (Side B)
1-803-615-21
A1 (Side B)
1-803-615-21
Address
Part No.
A1 (Side A)
1-576-122-21
A1 (Side A)
1-576-122-21
A2 (Side B)
1-576-329-21
Hold current
200 mA/25℃
200 mA/25℃
200 mA/25℃
200 mA/25℃
200 mA/25℃
500 mA/25℃
500 mA/25℃
Rating
0.4 A/72 V
0.4 A/72 V
10A/125V
1-12