Malfunction
The LEDs on the battery indi-
cate nothing.
1 LED on the battery blinks.
4 LEDs on the battery blink.
9.2
The rotary hammer is in working order
Trouble or fault
No hammering action.
The control switch can't be
pressed, i.e. the switch is
locked.
The drive spindle does not
rotate.
The rotary hammer switches
itself off automatically.
The battery runs down more
quickly than usual.
The battery does not en-
gage with an audible "double
click".
The rotary hammer or the
battery gets very hot.
The insert tool can't be re-
leased.
10
English
Possible cause
The battery is discharged.
The battery is too hot or too cold.
The battery is discharged.
The battery is too hot or too cold.
The rotary hammer has been over-
loaded briefly.
Possible cause
The rotary hammer is too cold.
The function selector switch is set
to "Drilling without hammering"
The forward / reverse switch is in
the middle position.
The permissible operating temper-
ature of the rotary hammer's elec-
tronics has been exceeded.
The battery is discharged.
The function selector switch is
not correctly engaged, is set to
"Chiseling"
, or is set to "Chisel
positioning"
.
The overload cut-out has been
activated.
Very low ambient temperature.
The retaining lugs on the battery
are dirty.
Electrical fault.
The rotary hammer has been over-
loaded.
The chuck is not pulled back fully.
Action to be taken
▶ Change the battery and charge
the empty battery.
▶ Allow the battery to cool
down or to warm up to room
temperature.
▶ Change the battery and charge
the empty battery.
▶ Allow the battery to cool
down or to warm up to room
temperature.
▶ Release the control switch and
then press it again.
Action to be taken
▶ Bring the tip of the drill bit
into contact with the working
surface, switch the rotary
hammer on and allow it to
run. If necessary, repeat the
procedure until the hammering
mechanism begins to operate.
▶ Set the function selector switch
.
to "Hammer drilling"
▶ Push the forward / reverse
switch to the right or left.
▶ Allow the tool to cool down.
▶ Change the battery and charge
the empty battery.
▶ Set the function selector switch
to "Drilling without hammering"
or "Hammer drilling"
▶ Release the control switch.
Allow the rotary hammer to cool
down. Press the control switch
again. Reduce the load on the
tool.
▶ Allow the battery to warm up
slowly to room temperature.
▶ Clean the retaining lugs and refit
the battery.
▶ Switch off the rotary hammer
immediately.
Remove the
battery and keep it under
observation. Allow it to cool
down. Contact Hilti service.
▶ Use a more powerful tool.
▶ Pull the chuck back as far as it
will go and remove the tool.
2166350
*2166350*
.
.