Siemens CP 1626 Operating Instructions Manual page 28

Communications processor
Table of Contents

Advertisement

Operating hardware
4.2 Diagnostics with SNMP
SNMP variable
Access rights
ifPhysAddress
Read only
ifSpecific
Read only
Note
The descriptions of the MIB objects not shown here can be found in the diagnostics manual
"SIMATIC NET Network Management Diagnostics and Configuration with SNMP".
Diagnostics manual (https://support.industry.siemens.com/cs/ch/en/view/103949062)
Port indexes
Port-specific objects can be addressed with "SNMP variable.portnumber".
For the CP 1626, the interface index corresponds to the port number.
Example
The "IfOperStatus.1" variable determines the operating state ("up", "down" etc.) of port 1 of
the CP 1626.
28
Description
Port MAC addresses of the CP 1626
Index 1: MAC address of the interface X1
Index 2 and 3: Port MAC address of the interface X1
Index 4: MAC address of the interface X2
Index 5 and 6: Port MAC address of the interface X2
Data type: PhysAddress
Specific reference
Here, a fixed value ".0.0" is used because there is no reference.
Data type: OBJECT IDENTIFIER
Operating Instructions, 11/2018, C79000-G8976-C434-03
CP 1626

Advertisement