Address space

The module can be configured in various ways in STEP 7. Depending on the configuration,
additional/different addresses are assigned in the process image output/input.
Configuration options of DQ 64x24VDC/0.3A BA
You can configure the module with STEP 7 (TIA Portal) or with a GSD file.
When you configure the module by means of the GSD file, the configurations are available
under different short designations/module names.
The following configurations are possible:
Table 4- 1
Configuration options
Configuration
1 x 64-channel without value status
8 x 8-channel without value status
1 x 64-channel with value status for module-
internal Shared Output (MSO) with up to 4 sub-
modules
18
Short designa-
tion/module name in the
GSD file
DQ 64x24VDC/0.3A BA
DQ 64x24VDC/0.3A BA S
DQ 64x24VDC/0.3A
BA MSO
Digital output module DQ 64x24VDC/0.3A BA (6ES7522-1BP00-0AA0)
Configuration software, e.g., with STEP
7 (TIA Portal)
Integrated in the
GSD file in STEP 7
hardware catalog
(TIA Portal) V12 or
of STEP 7
higher or STEP 7
(TIA Portal) as of
V5.5 SP3 or higher
V16 and HSP 0319
X
X
(PROFINET IO only)
(PROFINET IO only)
X