Mitsubishi Electric 700 Series Instruction Manual page 67

Hide thumbs Also See for 700 Series:
Table of Contents

Advertisement

Cyclic transmission
(1) Control information (inverter→master)
<Slave status>
Value
Slave status
0
FL remote network is not connected
1
FL remote network remote at a stop
2
FL remote network remote connection processing
3
FL remote network remote operating
4
Master is not present
5
Own node is disconnected
6
Setting error
<Actual slave type>
b15 b14 b13 b12 b11 b10 b9
<Simple setting check area>
Not used. (Displays data imported in the simple setting area set from the master.)
(2) Control information (master→inverter)
<Remote control area>
b15 b14 b13 b12 b11 b10 b9
<Expected slave type>
Refer to <Actual slave type>
<Simple setting check area>
Not used
56
Output points
H00 to H3F (One point to 64 point)
Subsequent area
0: Not used, 1:Used
0: Output not used (0 point)
1: Output used
b8
b7
Not used
b8
b7
b6
b5
b4
b3
Input points
H00 to H3F (One point to 64 point)
Subsequent area
0: Not used, 1: Used
0: Input not used (0 point)
1: Input used
b6
b5
b4
b3
b2
b1
b2
b1
b0
b0
Remote control flag
0: Remote control stop
1: Remote control start