No flame (bottom)(OTH_ID6)
Description The error message appears if the flame was detected during the first
Error gas blower (OTH_ID7)
Error gas blower (top)(OTH_ID8)
Error gas blower (bottom)(OTH_ID9)
Description
gas request at program start (feedback from ionization electrode
present) and then lost again (no feedback from ionization electrode).
For floor standing units, the error refers to the lower burner.
Troubleshooting
Troubleshooting as for error message No gas
Description
There is a communication error between the gas blower and the
ignition module. The device is no longer ready for operation.
Troubleshooting
Replace ignition module and communication cable to gas blower. If
the error persists, replace the gas blower.
Description
There is a communication error between the gas blower and the
ignition module. The device is no longer ready for operation.
Troubleshooting
Replace ignition module and communication cable to gas blower. If
the error persists, replace the gas blower.
Description
There is a communication error between the gas blower and the
ignition module. The device is no longer ready for operation.
Troubleshooting
Replace ignition module and communication cable to gas blower. If
the error persists, replace the gas blower.
Service-instructions
Fault messages & troubleshooting
113