Sinclair SDV5 Series Service Manual

Commercial air conditioners
Hide thumbs Also See for SDV5 Series:

Advertisement

Quick Links

INDOOR CONSOLE UNITS SDV5-XXPA
C O M M E R C I A L A I R C O N D I T I O N E R S S D V 5

Advertisement

loading

Summary of Contents for Sinclair SDV5 Series

  • Page 1 INDOOR CONSOLE UNITS SDV5-XXPA C O M M E R C I A L A I R C O N D I T I O N E R S S D V 5...
  • Page 2 Original instructions IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
  • Page 3: Table Of Contents

    Console Specifications ..................4 Dimensions .................... 5 Unit Placement ..................6 Piping Diagram ..................7 Wiring Diagram ..................8 Capacity Tables ..................10 Electrical Characteristics ..............16 Sound Levels ..................17 201807...
  • Page 4: Specifications

    1 Specifications SDV5-22PA / SDV5-28PA / SDV5-36PA / SDV5-45PA Table 1.1: SDV5-22,28,36,45PA specifications Model SDV5-22PA SDV5-28PA SDV5-36PA SDV5-45PA Power supply 1 phase, 220-240V, 50Hz Capacity Cooling kBtu/h 12.3 15.4 Power input Capacity Heating kBtu/h 10.9 13.6 17.1 Power input Model ZKSP-20-8-1 ZKSP-20-8-1 ZKSP-20-8-1...
  • Page 5: Dimensions

    2 Dimensions 2.1 Unit Dimensions Figure 2.1: Console dimensions (unit: mm) SDV5-22PA,SDV5-28PA, SDV5-36PA, SDV5-45PA 700mm 210mm 201807...
  • Page 6: Unit Placement

    3 Unit Placement 3.1 Placement Considerations Unit placement should take account of the following considerations:  Units should not be installed in the following locations:  Where exposure to direct radiation from a high-temperature heat source or to interference from a source of electromagnetic radiation may occur.
  • Page 7: Piping Diagram

    4 Piping Diagram Figure 4.1: Console piping diagram motor flare nut gas side heat exchanger flare nut liquid side Legend Indoor ambient temperature sensor Indoor heat exchanger mid-point temperature sensor Indoor heat exchanger outlet temperature sensor 201807...
  • Page 8: Wiring Diagram

    5 Wiring Diagram Figure 5.1: 2.2/2.8/3.6/4.5kW Console wiring diagram 201807...
  • Page 9  Notes for installers and service engineers Caution  All installation, servicing and maintenance must be carried out by competent and suitably qualified, certified and accredited professionals and in accordance with all applicable legislation.  Units should be grounded in accordance with all applicable legislation. Metal and other conductive components should be insulated in accordance with all applicable legislation.
  • Page 10: Capacity Tables

    6 Capacity Tables 6.1 Cooling Capacity Table Table 6.1: Console cooling capacity Indoor air temperature (°C WB/DB) Outdoor air Capacity 14/20 16/23 18/26 19/27 20/28 22/30 24/32 temperature (kW) (°C DB) 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0...
  • Page 11 Table 6.1: Console cooling capacity (continued) Indoor air temperature (°C WB/DB) Outdoor air Capacity 14/20 16/23 18/26 19/27 20/28 22/30 24/32 temperature (kW) (°C DB) 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 42.0 44.0...
  • Page 12 6.2 Heating Capacity Table Table 6.2: Console heating capacity Indoor air temperature (°C DB) Outdoor air Capacity temperature (°C) (kW) -19.8 1.46 1.46 1.46 1.46 1.46 1.46 -18.8 1.56 1.56 1.56 1.56 1.56 1.56 -16.7 1.64 1.64 1.64 1.64 1.64 1.64 -14.7 1.69...
  • Page 13 Table 6.2: Console heating capacity (continued) Indoor air temperature (°C DB) Outdoor air Capacity temperature (°C) (kW) -19.8 2.24 2.24 2.24 2.24 2.24 2.24 -18.8 2.40 2.40 2.40 2.40 2.40 2.40 -16.7 2.52 2.52 2.52 2.52 2.52 2.52 -14.7 2.60 2.60 2.60 2.60...
  • Page 14 Table 6.2: Console heating capacity (continued) Indoor air temperature (°C DB) Outdoor air Capacity temperature (°C) (kW) -19.8 3.53 3.53 3.53 3.53 3.53 3.53 -18.8 3.78 3.78 3.78 3.78 3.78 3.78 -16.7 3.97 3.97 3.97 3.97 3.97 3.97 -14.7 4.10 4.10 4.10 4.10...
  • Page 15 Table 6.2: Console heating capacity (continued) Indoor air temperature (°C DB) Outdoor air Capacity temperature (°C) (kW) -19.8 5.04 5.04 5.04 5.04 5.04 5.04 -18.8 5.40 5.40 5.40 5.40 5.40 5.40 -16.7 5.67 5.67 5.67 5.67 5.67 5.67 -14.7 5.85 5.85 5.85 5.85...
  • Page 16: Electrical Characteristics

    7 Electrical Characteristics Table 7.1: Console electrical characteristics Power supply Indoor fan motors Model Rated motor Volts Min. volts Max. volts output (kW) SDV5-22PA 220-240 0.37 0.02 0.29 SDV5-28PA 220-240 0.40 0.02 0.32 SDV5-36PA 220-240 0.42 0.02 0.33 SDV5-45PA 220-240 0.53 0.02 0.42...
  • Page 17: Sound Levels

    8 Sound Levels 8.1 Overall Table 8.1: Console sound pressure levels Figure 8.1: Console sound pressure level measurement Model Sound pressure levels dB(A) name SDV5-22PA SDV5-28PA SDV5-36PA SDV5-45PA Notes: Sound pressure levels are measured in a semi-anechoic chamber. During in-situ operation, sound pressure levels may be higher as a result of ambient noise.
  • Page 18 CONSOLE UNITS SDV5-22-45PA C O M M E R C I A L A I R C O N D I T I O N E R S S D V 5...
  • Page 19 SDV5-22PA...
  • Page 20 Description Part Code Note Qty Price Code MODEL: SDV5-22PA CONSOLE UNIT Evaporator ass'y 15826000002153 Input pipe ass'y 15426000001539 1.1.1 Electronic expansion valve 15500213000169 output pipe ass'y 15126000001316 11201007003022 Pipr temp sensor assembly Ventilation subassembly 12122600000153 display board installation support 12222700000052 Brushless DC Motor 11002015000190 Air filter...
  • Page 21 SDV5-28PA...
  • Page 22 Description Part Code Note Qty Price Code MODEL: SDV5-28PA CONSOLE UNIT Evaporator assembly 15826000002152 Input pipe ass'y 15426000001540 1.1.1 Electronic expansion valve 15500213000169 Output pipe ass'y 15126000001315 11201007003022 Pipr temp sensor assembly Ventilation subassembly 12122600000153 display board installation support 12222700000052 Brushless DC Motor 11002015000190 Air filter...
  • Page 23 SDV5-36PA...
  • Page 24 Description Part Code Note Qty Price Code MODEL: SDV5-36PA CONSOLE UNIT Evaporator ass'y 15826000002154 Input pipe ass'y 15426000001540 1.1.1 Electronic expansion valve 15500213000169 output pipe ass'y 15126000001315 11201007003022 Pipr temp sensor assembly Ventilation subassembly 12122600000153 display board installation support 12222700000052 Brushless DC Motor 11002015000190 Air filter...
  • Page 25 SDV5-45PA...
  • Page 26 Description Part Code Note Qty Price Code MODEL: SDV5-45PA CONSOLE UNIT Evaporator ass'y 15826000002154 Input pipe ass'y 15426000001540 1.1.1 Electronic expansion valve 15500213000169 output pipe ass'y 15126000001315 11201007003022 Pipr temp sensor assembly Ventilation subassembly 12122600000153 display board installation support 12222700000052 Brushless DC Motor 11002015000190 Air filter...
  • Page 27 SINCLAIR CORPORATION Ltd. 1-4 Argyll St. London W1F 7LD Great Britain www.sinclair-world.com This product was manufactured in China (Made in China). REPRESENTATIVE SINCLAIR Global Group s.r.o. Purkynova 45 612 00 Brno Czech Republic TECHNICAL SUPPORT SINCLAIR Global Group s.r.o. Purkynova 45...

This manual is also suitable for:

Sdv5-22paSdv5-28paSdv5-36paSdv5-45pa