Full dc inverter systems individual outdoor units (105 pages)
Summary of Contents for Sinclair SDV5 Series
Page 1
INDOOR CASSETTE UNITS SDV5-22-45CA C O M M E R C I A L A I R C O N D I T I O N E R S S D V 5...
Page 2
Original instructions IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
1 Specifications Table 1.1: SDV5-22-28-36-45CA specifications SDV5-22CA SDV5-28CA SDV5-36CA SDV5-45CA Model Power supply 1-phase, 220-240V, 50Hz Capacity Cooling kBtu/h 12.3 15.4 Power input Capacity Heating kBtu/h 10.9 13.6 17.1 Power input Model WZDK37-38G Type Fan motor Brand NIDEC/Welling/Match-Well Speed r/min 700/680/660/640/600/560/520 760/730/700/660/620/570/500 Number of rows...
3 Unit Placement 3.1 Placement Considerations Unit placement should take account of the following considerations: Units should not be installed in the following locations: Where exposure to direct radiation from a high-temperature heat source or to interference from a source of electromagnetic radiation may occur.
Page 7
Notes: The centerline of the maintenance hole should be in the same position as the centerline of the indoor unit.
Wiring Dia gram Figur re 5.1: Compact t Four‐way Cass s ette piping dia a gram wiring di iagram CN17 CN15 5 P5 XS5 White Black 3 XS3 Blue 9 ...
Page 10
Notes for installers and service engineers Caution All installation, servicing and maintenance must be carried out by competent and suitably qualified, certified and accredited professionals and in accordance with all applicable legislation. Units should be grounded in accordance with all applicable legislation. Metal and other conductive components should be insulated in accordance with all applicable legislation.
lectrical C Characteri istics ble 7.1: Compac ct Four‐way Cas ssette electrical l characteristics s wer supply Indoor fan motors Model name Rated motor Volts Min. vol Max. vol output (kW) SDV5-22CA 50 220‐240 0 0.43 15 0.037 0.344 SDV5-28CA 50 220‐240 0 ...
Page 27
Description Part Code Note Qty Price Code MODEL: SDV5-45CA CASSETTE FOUR-WAY UNIT 12222500000064 Ventilation ring 12122500000419 E-Part box cover ass'y 12226200000411 E-part box assembly 17226000002661 17400401001516 Wire joint Wire joint, 3p 17400401000157 Insulation plate 12122500000028 Chassis 12122500000462 Water collection foam assembly 12826000000190 centrifuge fan 12100103000076...
Page 28
SINCLAIR CORPORATION Ltd. 1-4 Argyll St. London W1F 7LD Great Britain www.sinclair-world.com This product was manufactured in China (Made in China). REPRESENTATIVE SINCLAIR Global Group s.r.o. Purkynova 45 612 00 Brno Czech Republic TECHNICAL SUPPORT SINCLAIR Global Group s.r.o. Purkynova 45...