Sinclair SDV5 User Manual

Full dc inverter systems
Hide thumbs Also See for SDV5:

Advertisement

MODULAR OUTDOOR UNITS SDV5-XXXEAM
C O M M E R C I A L A I R C O N D I T I O N E R S S D V 5

Advertisement

loading

Summary of Contents for Sinclair SDV5

  • Page 1 MODULAR OUTDOOR UNITS SDV5-XXXEAM C O M M E R C I A L A I R C O N D I T I O N E R S S D V 5...
  • Page 2 Original instructions IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
  • Page 3: Table Of Contents

    If this unit exhibits any abnormal behavior (such as emitting CONTENTS PAGE smoke) there is danger of serious injury or death. Disconnect the power supply and contact your dealer or service engineer immediately. IMPORTANT SAFETY INFORMATION............ PARTS NAMES..................This appliance can be used by children aged from 8 years and OPERATION AND PERFORMANCE............
  • Page 4: Parts Names

    Ensure the air inlet and outlet are not blocked or performance 3. OPERATION AND PERFORMANCE may suffer or it may activate protection, which will stop the unit from running. The cooling and heating operation in a VRF system In extremely strong winds, please prevent the air from flowing ●...
  • Page 5: Troubles And Causes

    4. TROUBLES AND CAUSES Explanation of heating operation ● It may take longer to reach the set temperature for general heating operation than for cooling operation. CAUTION The following operation is performed in order to prevent the heating capacity from dropping or cold air from blowing This unit should only be serviced and maintained by a ●...
  • Page 6: Malfunction

    5. MALFUNCTION Malfunction display of the outdoor unit’s DSP1 Table.5-1 Error Error description Remarks code Communication error between outdoor units Only displayed on the slave unit with the error Phase sequence error Displayed on the unit with the error Communication error between indoor and Only displayed on the master unit with the error master unit T3/T4 Temp.
  • Page 7: Button Function

    6. BUTTON FUNCTION Table 6-1 MENU Description Note DSP1 DSP2 Debug mode 1 Debug mode 2 Maintenance mode Reserved Reserved Backup run Vacuum mode Display“R006” History codes Cleaning history error Reserved MENU DOWN Restore factory settings Power limitation mode 1 Power limitation mode 2 6.1 Button switch function Power limitation mode 3...
  • Page 8 Menu function mode flowchart Start Press “menu” Long press “menu” 5 seconds Display “-n1” Press “menu” Press “up” or “down” to choose “X” Display “-nX” Press “menu” Press “OK” to confirm “X” Display “-nXY” Press “up” or “down” to choose “Y” Press “menu”...
  • Page 9 6.3 System check table Table 6-2 Press UP/DOWN button to enter system check mode when it is not in menu function mode DSP1 Remarks Parameters displayed on DSP2 content Unit address 8-32HP Unit capacity Number of outdoor units Number of indoor units as set on PCB Total capacity of outdoor unit Total capacity requirement of indoor units Total capacity requirement correction of master unit...
  • Page 10: Priority Mode 7

    Available for master unit Only available for master unit, displayed on slave units has no sense; Operation mode: 0-OFF; 2-Cooling; 3-Heating;4-Forced cooling Opening angle of EEV: Actual value=Display value*4(480P) or Actual value=Display value*24(3000P) Opening angle of EEV: Actual value=Display value*4(480P) High pressure: Actual value=Display value*0.1MPa Priority mode: 0-Auto priority, 1-cooling priority, 2-VIP priority or voting priority, 3-Heating only, 4-Cooling only...