Installation Manual
AQUA NEW STYLUS
Chilled Water Fan Coil
Convertible Type
CFEB Series 50/60 Hz
50 Hz Models
Cooling Only
CFEB 04 C0M1
CFEB 06 C0M1
CFEB 08 C0M1
CFEB 10 C0M1
CFEB 12 C0M1
CFEB 14 C0M1
CFEB 16 C0M1
CFEB 20 C0M1
60 Hz Models
Cooling Only
CFEB 04 C0M2
CFEB 06 C0M2
CFEB 08 C0M2
CFEB 10 C0M2
CFEB 12 C0M2
CFEB 14 C0M2
CFEB 16 C0M2
CFEB 20 C0M2
UNT-SVN009-EN
September 2009
UNT-SVN009-EN.p65
1
9/9/09, 9:56 AM

Advertisement

Table of Contents
loading

Summary of Contents for Trane AQUA NEW STYLUS CFEB Series

  • Page 1 Installation Manual AQUA NEW STYLUS Chilled Water Fan Coil Convertible Type CFEB Series 50/60 Hz 50 Hz Models Cooling Only CFEB 04 C0M1 CFEB 06 C0M1 CFEB 08 C0M1 CFEB 10 C0M1 CFEB 12 C0M1 CFEB 14 C0M1 CFEB 16 C0M1 CFEB 20 C0M1 60 Hz Models Cooling Only...
  • Page 2: General Information

    Your personal safety and the proper For installing the unit to operate Trane CFEB series of chilled water operation of this unit require that you properly and reliably, it must be fancoil systems offer three styles of follow them carefully.
  • Page 3: Table Of Contents

    Contents General Information Location and Preparation of Units Unit Installation Connection of Water Piping Position of Piping Hole Condensate Drain Piping Electrical Installation Remote Control Installation Electronic Room Thermostat Installation Typical Wiring Diagram Dimensional Data Notes UNT-SVN009-EN UNT-SVN009-EN.p65 9/9/09, 9:56 AM...
  • Page 4: Location And Preparation Of Units

    Location and Preparation of Units 1. Select an appropriate position that 5. Recommended service clearance allows every corner of the room as shown in figure 2, 3 and 4. to be uniformly air conditioned and where it is easy to route the water piping.
  • Page 5: Unit Installation

    Unit Installation 6. Unscrew at the return grille Indoor Unit (Figure 7). 1. Select a location to route piping, wiring and drain pipe. 2. Make a hole in the wall using a key hole saw or hole-cutting drill 8.5"(215) attachment. The hole should be made at a 0.83"(17.5) slight downward slant to the...
  • Page 6: Connection Of Water Piping

    Connection of Water Piping The unit water piping connections are provided with a make straight fitting. The water piping connection is located on the right hand side of the unit (Figure 11). To complete piping connections, connect the female connections to the male adapter of the water piping connections at the inlet and outlet of the coil.
  • Page 7: Condensate Drain Piping

    Condensate Drain Piping - The drain hose should run straight - When the drain hose is placed in down the wall to a level where the the room, insulate the hose with runoff will not stain the wall. foam polyethylene to avoid damage to the ceiling or furniture.
  • Page 8: Remote Control Installation

    Remote Control Installtion Locate and attach the wireless remote control and wired control as follows: 1. Do not place the control and 90.0 the remote control near heat sources or expose to the direct 61.0 rays of the sun. 14.5 14.5 2.
  • Page 9: Electronic Room Thermostat

    Electronic Room Thermostat Installation Precaution - This room thermostat is an - Room thermostat should not electronic control device, which be located at or near the water For better temperature control, requires special precaution for drop or water mist. please see the attached picture for installation.
  • Page 10: Typical Wiring Diagram

    Typical Wiring Diagram WIRING DIAGRAM UNT-SVN009-EN UNT-SVN009-EN.p65 9/9/09, 9:57 AM...
  • Page 11 Typical Wiring Diagram CFEB, CHILLED WATER FANCOIL UNIT WITH WIRELESS CONTROL COOLING ONLY UNT-SVN009-EN UNT-SVN009-EN.p65 9/9/09, 9:57 AM...
  • Page 12 Typical Wiring Diagram CFEB, CHILLED WATER FANCOIL UNIT WITH WIRED CONTROL COOLING ONLY UNT-SVN009-EN UNT-SVN009-EN.p65 9/9/09, 9:57 AM...
  • Page 13: Dimensional Data

    Dimensional Data CFEB04-12 (50/60 Hz) OUTLINE DIMENSIONS SLOT 215.0 [8.47] SLOT (MOUNTING HOLE) 27.5 [1.08] 17.5 [0.69] 17.5 [0.69] 74.0 [2.92] LENS FOR WIRELESS RETURN AIR REMOTE CONTROL 98.1 [3.87] 60.1 [2.37] RETURN AIR RUBBER ISOLATOR (QTY.= C) 74.2 [2.93] 234.3 [9.23] OUTLET CONNECTION INLET CONNECTION...
  • Page 14 Dimensional Data CFEB14-20 (50/60 Hz) OUTLINE DIMENSIONS SLOT 215.0 [8.47] 27.5 [1.08] 17.5 [0.69] 17.5 [0.69] 74.0 [2.92] LENS FOR WIRELESS RETURN AIR REMOTE CONTROL 98.1 [3.87] 60.1 [2.37] RETURN AIR 74.2 [2.93] RUBBER ISOLATOR 234.3 [9.23] (QTY.= C) OUTLET CONNECTION INLET CONNECTION 42.0 [1.65] 400.0 [15.76]...
  • Page 15 Notes UNT-SVN009-EN UNT-SVN009-EN.p65 9/9/09, 9:57 AM...
  • Page 16 Literature Order Number: UNT-SVN009-EN Date: Sep 2009 Supersedes: Apr 2008 Stocking Location: Bangkok, Thailand UNT-SVN009-EN.p65 9/9/09, 9:57 AM...

Table of Contents