11 / NOTICES
184
11.0d/
NEBS (Network Equipment Building System) Statement
An external SPD is intended to be used with G3100/E3200.
W W ARNING:
ARNING: The intra-building ports of the equipment or
subassembly is suitable for connection to intra-building or
unexposed wiring or cabling only. The intra-building port(s) of the
equipment or subassembly MUST NOT be metallically connected to
interfaces that connect to the OSP or its wiring. These interfaces
are designed for use as intra-building interfaces only (Type 4 ports
as described in GR-1089) and require isolation from the exposed
OSP cabling. The addition of Primary Protectors is not sufcient
protection in order to connect these interfaces metallically to OSP
wiring.