Read the following safety information. (continued)
 Avoid the generation of Corona discharge in an environment
where high voltage is applied to the sensor for a long time.
Depending on the frequency of the applied voltage and installation conditions
of the sensor, Corona discharge may be generated even when a voltage
lower than resisting voltage is applied to the sensor. This generation may lead
to degrading the insulating outer sheath, causing an electrical shock, fire, or
malfunction.
Corona discharge tends to be generated due to electric field concentration.
Take some measures to avoid the generation; for example, keep the sensor
away from high voltage parts as far as possible or achieve insulation.
 Do not put on this instrument a container that water, medicine,
etc. has entered or a small metallic object.
If not, an electric shock or fire may occur. If this instrument is wet with water, or
metal and other objects enter the instrument, immediately remove this
instrument from the object to be measured, power off the equipment
connected with this instrument, and turn the POWER switch to the O side to
turn off the power to this instrument (remove the AC adaptor from the receptacle
when used). After that, contact Iwatsu office or our sales distributors for repair.
 When it begins to thunder, pull out the power plug of a device or
the AC adaptor to which this instrument is connected from the
receptacle. Then, detach this instrument from the object to be
measured, and do not use it.
Lightning may be a cause of an electric shock, fire, or malfunction.
 Do not use this instrument when it has failed.
Using a failed instrument or, cable or AC adaptor may be a cause of an
electric shock or fire. In the event of a malfunction, contact Iwatsu office or
our sales distributors for repair.
 Turn off the power to the object to be measured before attaching
or detaching the Rogowski Coil Sensor of this instrument to or
from the object to be measured.
Failure to do so is very dangerous for objects to be measured that use high
voltage and high current.
 Be sure to use the free end of the Rogowski Coil while inserted in
the joint hall. Do not apply a high voltage exceeding the
specifications (refer to Section 5.1 "Specifications") to the
Rogowski Coil Sensor.
Failure to do so may cause an electric shock, fire, or malfunction.
 The sensor cable cannot be removed because it is integral with
(connected inside of) the main unit. Do not attempt to disconnect
the sensor cable.
Failure to do so may cause an electric shock, fire, or malfunction.