Display of Water Temperature:
Step 1: In Service Mode, Press the "Select" button until "Water Temp" is displayed in the upper right section of the water
heater display. This is the reading for the tank sensor.
To Display Flame Sense Current of the Pilot Flame Sensor:
The pilot flame sense current is available only when the burners are in operation. Step 1: Make sure the status displays
"Heating" or draw enough hot water to start the burners. Step 2: Enter the "Service Mode" described previously. Step 3:
Press the "Select" button until a number value is displayed with "Flame Current" to the right of the number. The value
displayed is in microamps (µA).
Water
°F
Temp
idle
Operational
Status
SELECT
SET
Current
µA
Heating
Status Operational
SELECT
SET
58