Disassembly And Repair - Rheem TRITON Service And Training Manual

80 & 100 gallon ultra-high efficiency water heaters
Table of Contents

Advertisement

Disassembly and Repair

Ignition Control Board
LCD Display
Blower Motor
Water Temperature Sensor
Triton Service Manual SVC1020T ; Rev 4
1. Disconnect power to the water heater.
2. Remove all Molex connections to the control board.
Wires are colored and the board locations have
numbers to reconnect. See Wiring Diagram on page 8
of this document.
3. Remove the three Phillips screws holding the control
board to the top of the water.
4. Remove the control and replace in reverse order.
1. Disconnect power to the water heater.
2. Disconnect the three Molex connections. One goes
to the ignition control board. The other 2 pigtail to
other wiring harness.
3. Remove the two Phillips screws holding the display
assembly to the top of the water.
4. Remove the display assembly and replace in reverse
order.
1. Disconnect power to the water heater.
2. Disconnect the 2 Molex connections.
3. Remove the two Phillips screws holding gas valve
and venturi assembly blower motor.
4. Remove the 4 Phillips screws holding the blower the
burner mounting flange.
5. Remove the blower and gasket from the burner mounting
flange.
6. Replace parts in the reverse order making sure to use the
new gaskets supplied with the blower. (There is a gasket for
the blower/burner mounting flange and another gasket for
where the gas valve and venturi assembly meets the
blower.)
1.Disconnect power to the water heater.
2.Drain the water in the tank to a point below the level of
the water temp sensor.
3.Remove all wiring connections to the sensor
assembly.
4.Remove the sensor assembly with a wrench.
5.Replace in reverse order.
5 0