EN 22
5.
EJ2.0U LA
Service Modes, Error Codes, and Fault Finding
37" 1366*768 LCD SHARP
Active
action holder: MIPS
Mute all sound outputs.
action holder: St-by
autonomous action
Switch reset-audio and sound-enable
lines high
switch off LCD lamp
Mute all video outputs
Wait 0ms. (No need to wait here
for the 37" Sharp panel)
Switch off LVDS signal
Switch off 12V LCD supply within a time frame of max.
1000ms after LVDS switch off.
(Viper I/O: LCD_PWR_ON)
Semi Standby
G_15940_046.eps
240506
Figure 5-9 "Active" to "Semi Stand-by" flowchart