Pivot Hole
Figure 2 Duplex Paper Guide Pivots (Rear View)
Replacement
The replacement is the reverse of the removal procedure.
Repairs / Adjustments
REP 4.6, REP 4.7
Pivot Cutout
REP 4.7 Output Tray Full Sensor
Parts List on
PL 4.3
Removal
1.
Switch off the machine, then disconnect the power cord.
2.
Remove the Middle Cover,
NOTE: Do not disconnect the connectors to the Main PWB. The PWB only needs to be moved
away from the frame to access the Output Tray Full Sensor.
NOTE: Mark the location of the Ground Screw, with larger head, so it can be re-installed in the
correct location.
3.
Remove five screws, then move the Main PWB away from the printer frame,
July 2019
4-24
REP
2.5.
Figure 1 Main PWB
Xerox® B205/B215 Multifunction Printer Service Manual
Figure
1.
Initial Release