Core 1 Screen - Siemens SIJECT 16i Operation Manual

Hide thumbs Also See for SIJECT 16i:
Table of Contents

Advertisement

SIJECT OP15B Screens

3.2.6 Core 1 screen

Operating sequences
3-46
Fig 3-39
Core 1 in/out --- screen 1
Press the Core 1 key to enter Core 1 screen. See Fig 3-39.
The screen displays the core 1 in/out status, and the related parameters
can be set here, including the position, pressure, flow, time and counter.
The core operation can be controlled by position, by time, or by counter.
Core 1 in
set the pressure and flow for core 1 in. If it is by position, then
position value should be set. If it is by time, then the time should be set as
a parameter and the actual time will be displayed. If it is by counter, then
the counter should be set and the actual counting value will be displayed.
Core 1 out
set the pressure and flow for core 1 out. If it is by position,
then position value should be set. If it is by time, then the time should be
set as a parameter and the actual time will be displayed. If it is by counter,
then the counter should be set and the actual counting value will be
displayed.
Core 1 selection (CorSelect)
Core 1 mode (CorMode)
mode.
Core in position (CorInPos)
can be at the start of mold close, during mold close, or at the end of mold
close.
Core out position (CorOutPos)
core out can be at start of mold close, during mold close, or at the end of
mold close.
Mold position (MldPos)
Press Manual Core 1 in key
Core 1 out key
to do core out.
select or deselect core 1 in/out.
select position mode, time mode or counter
set the position to do core in. The core in
set the position to do core out. The
display the current position of mold.
to do core in manually, and press Manual