Ejector Screen - Siemens SIJECT 16i Operation Manual

Hide thumbs Also See for SIJECT 16i:
Table of Contents

Advertisement

SIJECT OP15B Screens

3.2.2 Ejector screen

Operating sequences
3-40
Fig 3-35
Ejector screen
Press the middle key to enter the ejector screen. See Fig 3-35.
Four status of the ejector advance / retract are displayed on the screen:
ejector advance 1, ejector advance 2, ejector retract 1 and ejector retract 2.
All related parameters can be set here, including position, pressure, flow
and counter. When Vibrate is selected, then the vibration position can also
be set.
Ejector advance 1 (EjeAdv 1)
position, pressure and flow for ejector advance 1.
Ejector advance 2 (EjeAdv 2)
position, pressure and flow for ejector advance 2.
Ejector retract 1(EjeRet 1)
position, pressure and flow for ejector retract 1.
Ejector retract 2(EjeRet 2)
position, pressure and flow for ejector retract 2.
Vibrating position (Vibrate)
position and then advances. This is so called vibration ejection.
Ejector backward indicator (EjeBck)
position, this indicator will backlight, indicating that the end position signal
has been detected.
Ejector mode (EjeMode)
mode. Once mode: ejector advances after mold open, but it will not retract.
Multiple mode: ejector advances and retracts to the end position, then
advances again. It advances and retracts according to the set numbers.
Vibration mode: ejector advances and retracts to the set position, then
advances again. It advances and retracts according to the set numbers. If
this item is deselected, that means this machine does not use ejector.
Ejector position (EjePos)
During ejector advance, users can set
During ejector advance, users can set
During ejector retract, users can set
During ejector retract, users can set
Set position here. Ejector retracts to this
when ejector retracts to the end
users can select once, multiple or vibration
display the actual position of ejector
SIJECT 16i Operation Manual