ABB IRC5 Applications Manual page 80

Profinet controller/device
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

C Using PROFINET Configurator Express
Continued
7
8
9
Continues on next page
80
Action
Right-click on Phoenix Contact Software PROFINET and select Insert Device into
Bus structure.
This node now represents the IRC5 controller master.
In the Bus Structure window, select Phoenix Contact Software PROFINET to bring
up the Device Details window.
xx1600000030
These values does not have any effect on the IRC5 controller settings, but could be
filled with data to reflect the settings of the IRC5 controller that is using this configur-
ation.
Install the GSDML file for the ET200s Standard device by right-clicking in the Device
Catalog window and select Import GSD file.
xx1600000031
In this example, install the GSDML-V2.2-Siemens-ET200S-20090309.xml file.
This version of the PROFINET-IO Configurator Express support V2.2 syntax and
earlier versions for the GSDML files.
The installation of the GSDML file may take several minutes and the program might
appear to be unresponsive during that time.
© Copyright 2015-2018 ABB. All rights reserved.
Application manual - PROFINET Controller/Device
3HAC050969-001 Revision: G