6.4 Type Signal

6.4.1 Transfer To Device

Parent
Transfer To Device belongs to the type Signal, in the topic I/O System.
Cfg name
TransferToDevice
Description
The parameter Transfer To Device specifies that the signal shall be transferred to
the internal device starting at the offset specified in the parameter Output Offset
On Destination Device.
Prerequisites
The option PROFINET Controller/Device must be installed.
Limitations
Only signals of type Digital Output/ Digital Input/ Group Output/ Group Input can
be transferred. The destination I/O device can only be the PROFINET internal
device.
Allowed values
The allowed value is the PROFINET internal device.
Application manual - PROFINET Controller/Device
3HAC050969-001 Revision: G
© Copyright 2015-2018 ABB. All rights reserved.
6 System parameters
6.4.1 Transfer To Device
PROFINET Controller/Device
63