2 Hardware overview
2.1 Main computer
Continued
Using Anybus adapter to connect two PROFINET networks
PROFINET on shared factory network and private network
To be able to use PROFINET on both the public and the private network, an Anybus
adapter must be used. If the same factory network is used both for PROFINET
communication and other communication, both the Anybus adapter and the WAN
port must be connected to the factory network. For information about the PROFINET
Anybus adapter, see Application manual - PROFINET Anybus Device.
xx1500000475
PROFINET on dedicated industrial network
If the PROFINET communication is separated from other communication, an Anybus
adapter must be connected to the PROFINET industrial network and the WAN port
must be connected to the factory network.
If the PROFINET communication shall be separated from other Ethernet
communication, an Anybus adapter must be installed and connected to the public
PROFINET industrial network and the WAN port connected to the factory network.
Continues on next page
24
Factory Network
PROFINET
Anybus
adapter
Robot Controller 1
Private
Service
LAN 2
LAN 3
LAN 1
I/O
I/O
Robot I/O
© Copyright 2015-2018 ABB. All rights reserved.
Public
WAN
PROFINET
Application manual - PROFINET Controller/Device
PLC
PROFINET
Robot Controller 1
Private
Service
LAN 2
LAN 3
LAN 1
I/O
I/O
Robot I/O
3HAC050969-001 Revision: G
Anybus
adapter
Public
WAN
PROFINET

Hide quick links: