9. Maintenance
Cleaning the scanning glass and rollers
Clean the scanning glass and rollers frequently to ensure the quality of
your transmitted images and copies.
1
Grasp the finger hold and pull up to
open the operation panel.
2
Flip up the green levers on each side
of the white roller.
3
Wipe the scanning glass and rollers
with a cotton pad.
• Make sure that all dirt and stains
(such as correcting fluid) are
removed, as dirt will cause vertical
lines on transmitted images and
copies.