York F*FP Technical Manual page 4

Single piece air handlers for use with split-system cooling & heat pumps
Table of Contents

Advertisement

ACCESSORIES
Refer to Price Manual for specific model numbers.
VERTICAL SUSPENSION KIT - The suspension kit is
designed to be used with all sizes of fan coil units whenever
the application requires vertical suspension of the unit.
ELECTRIC HEATERS - Models shown under Electrical Data
include sequencers and temperature dual limit switches for
safe, efficient operation. Circuit breakers are provided where
shown.
BOLT-ON THERMAL EXPANSION VALVE - TXV kits are
available for enhanced efficiency. These fan coil units have
factory installed TXV's.
EXTENDED AIRFLOW DATA
Blower Motor
Models
Speed
High
F4FP024H06T2*
Med
Low
High
F4FP030H06T2*
Med
Low
High
F4FP036H06T2*
Med
Low
High
F4FP040H06T2*
Med
Low
High
F4FP042H06T2*
Med
Low
High
Med High
F4FP045H06T2*
Med Low
Low
High
Med High
F5FP048H06T2*
Med
Med Low
Low
High
Med High
F5FP060H06T2*
Med
Med Low
Low
High
F4FV060H06T2*
Med.
Low
NOTE: Air flow data shown above 0.50" W.C. external static pressure is for REFERENCE ONLY. Maximum allowable external static when electric heat is used is
limited to 0.50" W.C. Maximum allowable external static pressure may also be limited by minimum CFM requirements for proper Heat Pump operation.
1. Includes Return Air Filter and Largest Electric Heater.
All F*FP series air handler units are UL Listed up to 0.50" w.c. external static pressure, including air filter, wet coil, and largest KW size heater.
4
1
FOR 230 VOLT - HEAT PUMP MODELS
0.10
0.20
0.30
950
910
865
845
815
785
650
630
605
1,270
1,210
1,150
1,050
1,040
995
855
820
780
-
1,310
1,250
1,200
1,150
1,100
1,060
1,015
970
1,270
1,210
1,150
1,050
1,040
995
855
820
780
-
1,575
1,500
1,460
1,395
1,330
1,250
1,200
1,155
1,575
1,535
1,475
1,375
1,315
1,255
1,210
1,160
1,110
1,035
990
940
2223
2158
2090
1948
1904
1801
1741
1690
1649
1499
1454
1415
1286
1233
1177
2195
2145
2070
1938
1899
1873
1726
1681
1641
1525
1483
1441
1306
1254
1204
2,285
2,195
2,105
2,125
2,020
1,910
1,655
1,605
1,550
LIMITATIONS
These units must be wired and installed in accordance with
all national and local safety codes. Voltage limits are as fol-
lows:
Normal Operating voltage Range
1. Utilization range "A" in accordance with ARI Std. 110.
Air flow must be within the minimum and maximum limits
approved for electric heat, evaporator coils and outdoor units:
Entering Air Temperature Limits
Wet Bulb Temp. ºF
Min.
Max.
57
230 Volt
CFM @ External Static Pressure - IWC
0.40
0.50
0.60
835
775
730
745
705
654
575
540
508
1,085
1,015
946
930
855
804
735
680
624
1,175
1,120
1,053
1,040
985
933
925
860
809
1,085
1,015
946
930
855
804
735
680
624
1,420
1,350
1,273
1,260
1,190
1,125
1,100
1,050
1,001
1,390
1,310
1,245
1,185
1,110
1,040
1,050
980
921
890
825
770
2029
1929
1861
1815
1777
1741
1606
1564
1516
1370
1328
1269
1142
1092
1039
2008
1920
1852
1824
1791
1724
1607
1560
1517
1383
1356
1291
1160
1114
1061
2,015
1,950
1,845
1,805
1,705
1,597
1,500
1,450
1,398
295421-YTG-B-0707
1
187-253
Dry Bulb Temp. ºF
Min.
72
65
0.70
0.80
0.90
662
590
502
594
524
439
450
383
285
862
769
645
714
624
494
550
447
333
983
894
779
879
795
711
740
661
572
802
769
645
714
624
494
550
447
333
1,192
1,102
996
1,052
960
842
931
851
751
1,147
1,030
897
944
848
732
844
737
640
698
616
524
1788
1679
1594
1681
1618
1539
1476
1436
1387
1228
1191
1132
987
960
888
1754
1663
1570
1679
1603
1521
1485
1433
1402
1253
1208
1169
1008
980
914
1,770
1,685
1,590
1,491
1,386
1,280
1,326
1,245
1,153
Unitary Products Group
Max.
95
1.00
400
344
158
502
364
190
645
587
453
502
364
190
871
695
631
735
606
533
432
1501
1453
1353
1093
842
1462
1420
1349
1123
876
1,485
1,175
1,052