Cooling Capacities - 4 Ton - York SUNLINE 2000 2000 Technical Manual

Single package air-to-air heat pumps (208/230, 460v, 575v) 3, 4 and 5 nominal tons (10 seer)
Table of Contents

Advertisement

036-21564-003-A-1005
COOLING CAPACITIES -
Air On
Indoor
Coil
Total
Cap.
WB
CFM
°F
MBH
72
56
67
53
2000
62
49
57
49
72
55
67
52
1800
62
48
57
48
72
53
67
51
1600
62
47
57
47
72
52
67
49
1400
62
46
57
45
72
50
67
47
1200
62
44
57
44
Air On
Indoor
Coil
Total
WB
Cap.
CFM
°F
MBH
72
51
67
46
2000
62
43
57
43
72
50
67
45
1800
62
42
57
42
72
49
67
44
1600
62
41
57
41
72
47
67
42
1400
62
39
57
39
72
44
67
40
1200
62
38
57
37
1
These capacities are gross ratings. For net capacity, determine the KW of the supply air blower motor from the Blower Performance Table, multiply this value by
3.415 MBH / KW to determine the motor heat, and deduct this heat from the gross capacity of the unit.
2
These ratings include the compressor and the outdoor fan motors but not the supply air blower motor. The total outdoor fan motor power input is 0.35 KW.
Refer to the Blower Performance Table for the KW of the supply air blower motor.
NOMINAL RATING
Unitary Products Group
4 TON (BCH048)
85 °F
Sensible Capacity
Power
1
2
Entering Dry Bulb, °F
Input
KW
86
83
80
77
4.1
42
36
31
26
4.0
48
47
41
36
4.0
49
49
48
44
3.9
49
49
49
44
4.0
40
35
30
25
4.0
47
44
39
34
3.9
48
48
47
43
3.9
48
48
48
43
4.0
37
33
28
24
4.0
46
42
37
33
3.9
47
47
46
41
3.9
47
47
47
42
4.0
34
30
26
22
3.9
42
38
34
30
3.8
46
45
42
38
3.8
45
45
43
39
3.9
31
27
24
20
3.9
38
35
31
28
3.8
44
42
39
35
3.7
44
43
39
36
105 °F
Sensible Capacity
Power
1
2
Entering Dry Bulb, °F
Input
KW
86
83
80
77
4.9
40
35
29
24
4.7
42
42
39
34
4.6
43
43
42
37
4.6
43
43
43
38
4.8
38
33
28
23
4.7
41
41
37
32
4.6
42
42
41
37
4.5
42
42
42
37
4.8
35
31
26
22
4.6
40
40
35
31
4.5
41
41
40
35
4.4
41
41
41
36
4.7
32
28
24
20
4.5
38
36
32
28
4.4
39
38
37
33
4.4
39
39
37
33
4.6
28
25
21
18
4.5
36
32
29
25
4.4
38
36
34
29
4.3
37
37
34
30
Temperature of Air on Outdoor Coil
1
, MBH
Total
Power
1
Cap.
Input
MBH
KW
74
71
68
-
-
-
53
4.5
30
25
-
51
4.4
38
33
28
46
4.3
38
33
28
46
4.3
-
-
-
53
4.4
29
24
-
51
4.4
38
33
28
47
4.3
38
33
28
45
4.2
-
-
-
52
4.4
28
24
-
50
4.3
37
32
28
45
4.2
38
33
29
44
4.1
-
-
-
49
4.3
26
22
-
47
4.2
34
30
26
43
4.1
35
31
27
42
4.1
-
-
-
47
4.2
24
21
-
45
4.2
32
28
25
40
4.1
32
29
25
40
4.0
Temperature of Air on Outdoor Coil
1
, MBH
Total
Power
1
Cap.
Input
MBH
KW
74
71
68
-
-
-
49
5.2
28
23
-
41
5.0
32
27
21
40
4.9
32
28
22
40
4.8
-
-
-
47
5.1
27
22
-
40
4.9
32
27
22
39
4.8
33
27
23
38
4.7
-
-
-
46
5.1
26
22
-
39
4.9
32
27
23
37
4.7
32
28
23
37
4.7
-
-
-
44
5.0
24
20
-
37
4.8
28
25
20
36
4.7
29
25
21
36
4.6
-
-
-
42
4.9
22
18
-
36
4.7
27
22
20
35
4.6
27
23
20
35
4.6
ALL SENSIBLE CAPACITY
95 °F
1
Sensible Capacity
, MBH
2
Entering Dry Bulb, °F
86
83
80
77
74
40
35
29
24
-
46
45
41
35
30
46
46
45
41
35
46
46
46
41
35
38
33
28
23
-
44
44
39
34
29
47
47
45
40
36
45
45
45
40
35
36
32
27
23
-
44
43
38
34
29
45
45
44
40
36
44
44
44
40
36
33
29
25
21
-
42
38
34
30
26
43
42
40
36
32
42
42
40
36
32
29
25
22
18
-
37
34
30
27
23
40
39
36
32
29
40
39
36
32
29
115 °F
1
Sensible Capacity
, MBH
2
Entering Dry Bulb, °F
86
83
80
77
74
39
34
29
23
-
40
40
37
32
26
40
40
39
34
29
40
40
40
34
30
37
32
27
22
-
37
36
35
30
25
39
39
37
34
29
38
38
38
33
30
34
29
25
20
-
36
36
32
28
23
37
37
36
33
28
37
37
37
34
28
31
27
23
19
-
36
34
30
26
21
36
35
34
30
26
36
36
34
31
26
28
24
21
17
-
34
31
27
24
20
35
34
30
28
24
35
35
31
29
24
71
68
-
-
24
-
30
24
30
24
-
-
24
-
31
26
30
25
-
-
25
-
31
27
31
27
-
-
22
-
28
24
28
24
-
-
20
-
25
22
25
22
71
68
-
-
21
-
23
18
24
19
-
-
20
-
24
19
25
20
-
-
19
-
24
19
25
20
-
-
17
-
22
18
23
19
-
-
17
-
20
17
21
18
5