4. Remove the EMC shield from the rear of the server.
a. If there are two SMP Expansion Modules installed in the server, you must dis-
connect the SMP Expansion Cables that are connected to the SMP Expan-
sion Modules.
b. Remove the blue thumbscrews holding the EMC shield to the server.
For use with one
SMP Module
c. Remove the EMC shield from the rear of the server.
5. Grasp each of the locking levers on the top of the SMP modules, and lift them up
slightly.
6. Working from the right side of the server, rotate the two locking levers toward you
until they are fully extended, as shown.
EMC shields
Thumbscrews
For use with two
SMP Modules
SMP Expansion
Cables
EMC Shield
SMP baffle
Chapter 2. Installing options
15