Belt Drive Blower Motor And Drive Data . 10 Supply Air Blower Performance (6 Ton Belt Drive) - Side Duct Application; Static Resistances; Electric Heater Cfm Limitations - York DF 072 Technical Manual

Single package gas/electric units and single package air conditioners
Table of Contents

Advertisement

254599-YTG-C-0807
TABLE 8: SUPPLY AIR BLOWER PERFORMANCE (6 TON BELT DRIVE) - SIDE DUCT APPLICATION
Unit
Motor
Tonnage
Speed
CFM
Hi
2256
Med/Hi
2145
2
6
Med
2020
Med/Low
-
Low
-
Unit
Motor
Tonnage
Speed
CFM
Hi
2125
Med/Hi
2014
2
6
Med
1876
Med/Low
-
Low
-
1. Includes allowances for a wet evaporator coil, 1" filters, and the heat exchangers. Refer to STATIC RESISTANCES
Table for resistance values.
2. Side Duct application (230 Volts)
TABLE 9: STATIC RESISTANCES
DESCRIPTION
1 3
ECONOMIZER
ELECTRIC
7-15KW
1
HEATERS
20-30KW
BOTTOM DUCT CONNECTIONS
2
COOLING ONLY
1. Deduct these resistance values from the available external static pressure shown in SUPPLY AIR BLOWER PERFORMANCE Tables.
2. Add these resistance values to the available static resistance values on SUPPLY AIR BLOWER PERFORMANCE Tables.
3. The pressure through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air
duct system is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation.
TABLE 10: ELECTRIC HEATER CFM LIMITATIONS
UNIT MODEL SIZE NOMI-
NAL TONS
6
Unitary Products Group
Available External Static Pressure - IWG
0.2
0.3
Watts
CFM
Watts
883
2258
931
771
2127
784
637
1999
656
-
-
-
-
-
-
Available External Static Pressure - IWG
0.7
0.8
Watts
CFM
Watts
971
2044
940
859
1965
861
730
1832
740
-
-
-
-
-
-
1000
1200
1400
0.07
0.08
0.09
0.04
0.05
0.06
0.06
0.07
0.08
1
0.06
0.07
0.08
0.08
0.10
0.12
VOLTAGE
208/230-3-60
460-3-60
575-3-60
0.4
0.5
CFM
Watts
CFM
2247
950
2223
2119
808
2089
1985
675
1947
-
-
-
-
-
-
1
0.9
1.0
CFM
Watts
CFM
1958
898
1864
1896
843
1801
1793
756
-
-
-
-
-
-
-
RESISTANCE, IWG
CFM
1600
1800
2000
0.11
0.13
0.15
0.07
0.08
0.10
0.09
0.11
0.13
0.09
0.10
0.11
0.14
0.16
0.18
MINIMUM SUPPLY AIR CFM
HEATER SIZE NOMINAL KW
5
7
10
1800
1800
1800
-
1800
1800
-
-
1800
1
0.6
Watts
CFM
Watts
964
2182
979
826
2051
844
696
1910
715
-
-
-
-
-
-
Watts
854
806
-
-
-
2200
2400
2600
0.17
0.20
0.23
0.12
0.14
0.16
0.15
0.17
0.20
0.12
0.14
0.16
0.20
0.23
0.26
15
20
1800
1800
1800
1800
1800
1800
2800
3000
0.26
0.30
0.19
0.22
0.23
0.26
0.19
0.22
0.29
0.32
30
1800
1800
1800
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents