TABLE 11: ELECTRICAL DATA - DF072 BELT DRIVE W/O POWERED CONV. OUTLET
COMPRESSORS
MODEL
VOLTAGE
RLA
TONNAGE
EACH
208-3-60
20.7
230-3-60
20.7
DF072
(6.0)
460-3-60
10.0
575-3-60
8.2
1. HACR Type per NEC.
2. These electric heaters do not include a fuse box. If a fuse box is required to meet a local code (i.e. Chicago), the fuse block
accessories 2FB04700825 and 2FB04700846 are available for field installation.
TABLE 12: ELECTRICAL DATA - DF072 DIRECT DRIVE W/O POWERED CONV. OUTLET
COMPRESSORS
MODEL
VOLTAGE
RLA
TONNAGE
EACH
208-3-60
20.7
DF072
(6.0)
230-3-60
20.7
1. HACR Type per NEC.
2. These electric heaters do not include a fuse box. If a fuse box is required to meet a local code (i.e. Chicago), the fuse block
accessories 2FB04700825 and 2FB04700846 are available for field installation.
12
ID
OD FAN
BLOWER
MOTOR
LRA
MOTOR
FLA
EACH
FLA
156.0
2.3
5.2
156.0
2.3
5.2
75.0
1.3
2.6
54.0
1.3
2.0
ID
OD FAN
BLOWER
MOTOR
LRA
MOTOR
FLA
EACH
FLA
156.0
2.3
10.6
156.0
2.3
10.6
CONV
ELECTRIC HEATER
OUTLET
MODEL NO.
FLA
None
2
2CE04510525
2
2CE04510725
0.0
2CE04511025
2CE04511525
2CE04512025
2CE04513025
None
2
2CE04510525
2
2CE04510725
0.0
2CE04511025
2CE04511525
2CE04512025
2CE04513025
None
2
2CE04510746
2
2CE04511046
0.0
2
2CE04511546
2
2CE04512046
2
2CE04513046
None
2CE04511058
0.0
2CE04511558
2CE04512058
2CE04513058
CONV
ELECTRIC HEATER
OUTLET
MODEL NO.
FLA
None
2
2CE04510525
2
2CE04510725
0.0
2CE04511025
2CE04511525
2CE04512025
2CE04513025
None
2
2CE04510525
2
2CE04510725
0.0
2CE04511025
2CE04511525
2CE04512025
2CE04513025
254599-YTG-C-0807
MIN.
HEATER
HEATER
CIRCUIT
KW
AMPS
AMPACITY
(AMPS)
-
-
33.4
4
11.1
33.4
5.6
15.5
33.4
8
22.2
34.3
11.9
33.0
47.8
15.9
44.1
61.7
22.2
61.6
83.5
-
-
33.4
5.3
12.7
33.4
7.5
18.0
33.4
10.6
25.5
38.4
15.9
38.2
54.3
21.2
51.0
70.2
29.6
71.2
95.5
-
-
16.4
6.8
8.2
16.4
10.1
12.1
18.4
13.6
16.4
23.7
19.5
23.5
32.6
28.8
34.6
46.6
-
-
13.3
10.6
10.2
15.2
15.9
15.3
21.6
21.2
20.4
28
30.4
29.3
39.1
MIN.
HEATER
HEATER
CIRCUIT
KW
AMPS
AMPACITY
(AMPS)
-
-
38.8
4.0
11.1
38.8
5.6
15.5
38.8
8.0
22.2
41.0
11.9
33.0
54.5
15.9
44.1
68.4
22.2
61.6
90.3
-
-
38.8
5.3
12.7
38.8
7.5
18.0
38.8
10.6
25.5
45.1
15.9
38.2
61.1
21.2
51.0
77.0
29.6
71.2
102.3
Unitary Products Group
MAX. FUSE/
1
BRKR
SIZE
(AMPS)
45
45
45
45
50
70
90
45
45
45
50
60
80
100
25
25
25
25
35
50
20
20
25
30
40
MAX. FUSE/
1
BRKR
SIZE
(AMPS)
50
50
50
50
60
70
100
50
50
50
50
70
80
110

Hide quick links: