 CAUTION
This system uses R-410A refrigerant which operates
at higher pressures than R-22. No other refrigerant
may be used in this system. Gage sets, hoses,
refrigerant containers and recovery systems must be
designed to handle R-410A. If you are unsure, consult
the equipment manufacturer. Failure to use R-410A
compatible servicing equipment may result in property
damage or injury.
 WARNING
FIRE OR EXPLOSION HAZARD
If the information in this manual is not followed
exactly, a fire or explosion may result causing property
damage, personal injury or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
Due to system pressure, moving parts, and electrical
components, the installation and servicing of
air conditioning equipment can be hazardous.
Only qualified, trained service personnel must
install, repair, or service this equipment. Untrained
personnel can perform basic maintenance functions
of cleaning coils and filters, and replacing filters.
Observe all the precautions in the literature, labels,
and tags that accompany the equipment whenever
you work on air conditioning equipment. Be sure to
follow all other applicable safety precautions and
codes including ANSI Z223.1 or CSA-B149.1- latest
edition.
Wear safety glasses and work gloves. Use
quenching cloth and have a fire extinguisher
available during brazing operations.
This unit is classified as APPLIANCE NOT ACCESSIBLE
TO GENERAL PUBLIC.
6
Installation Manual: YORK
Sun™ Select YV28 to YV50
®
Johnson Controls Ducted Systems

Inspection

As soon as you receive a unit, you must inspect
it for possible damage during transit. If damage
is evident, note the extent of the damage on the
carrier's freight bill. You must make a separate
request for inspection by the carrier's agent in
writing.
 CAUTION
This product must be installed in strict compliance
with the enclosed installation instructions and any
applicable local, state and national codes including,
but not limited to, building, electrical, and mechanical
codes.
The furnace and its individual shut-off valve must
be disconnected from the gas supply piping system
during any pressure testing at pressures in excess of
1/2 psig. Pressures greater than 1/2 psig will cause
gas valve damage resulting in a hazardous condition.
If it is subjected to a pressure greater than 1/2 psig,
the gas valve must be replaced.
The furnace must be isolated from the gas supply
piping system by closing its individual manual shut-
off valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than
1/2 psig.

Reference

Additional information is available in the following
reference forms:
Technical Guide - 5759098
General Installation - 5759090
Smart Equipment™ Control Quick Start Guide -
1136326

Renewal parts

Contact your local York
®
for authorized replacement parts.

Approvals

The design is certified by CSA as follows:
For use as a cooling only unit, cooling unit
with supplemental electric heat, or a forced air
furnace.
For outdoor installation only.