[Password]
The keyboard for setting the password is displayed. After
entering the password, select [Ok]; the confirmation
screen is displayed. Enter the password again and
select [Ok]; the password is determined.
Entering characters (see page 154)
[Save]
Saves the settings above in the display unit.
Note
The default password is "1111".
The security password is used when performing
[Shipping] and [Network settings] - [Reset].
Change the password at a regular interval to make it
hard to be guessed.
For how to initialize the security password, consult
your dealer.
[Shipping]
Restores the data of this unit to the factory default state.
For more detail of the settings, see "Shipping condition".
(see page 158)
Note
When [Security password] - [Security password] is set
to [On], it is necessary to input the password before
performing [Shipping].

Control settings

Sets each item of the function which enables to control
multiple displays at the same time, or individually.
[Control settings] - submenu screen
Control settings
Display ID
Controller ID function
Serial ID function
Serial response (Normal)
Serial response(ID all)
[Display ID]
Set ID number when controlling the Display with
[Controller ID function] and [Serial ID function].
0 to 100 (Standard value: 0)
[Controller ID function]
Enables/disables the [Controller ID function].
[Off]:
Disables the [Controller ID function]. (Can be
operated as normal remote control.)
[On]:
Enables the [Controller ID function]. Effective on
switching to [On].
Note
To use the [Controller ID function], setting ID numbers
both for the remote control and for the display unit is
required.
For ID number setting for the remote control, see
page 153.
About how to reset the settings to defaults, refer to
"Initialization". (see page 159)
106
English
0
Off
Off
On
Off
[Serial ID function]
Set to control external control with the PC connected to
SERIAL terminal according to the Display's ID number.
[Off]:
Disables external control by the ID.
[On]:
Enables the external control by the ID.
[Serial response (Normal)]
Sets whether to send the response command to normal
commands without ID.
[Off]:
Does not respond. (Including the inquiry
command)
[On]:
Responds.
[Serial response(ID all)]
Set whether to respond to the command or not, when
serial command of ID number "0" is received.
[Off]:
Does not respond.
[On]:
Responds.

Information timing

Set up the informing manner for no signal or
temperature rising.
RS-232C controls:
Warning or error message sent from the display
automatically.
LAN controls:
Acquire the warning or error message from the
display.
[Information timing] - submenu screen
Information timing
No signal warning
No signal warning timing
No signal error
No signal error timing
Temperature warning
[No signal warning]
When set to [On], the display sends out the no signal
warning.
[No signal warning timing]
Set up the detecting time for no signal warning.
(Range: 01 ‒ 60, Interval: 1 minute)
[No signal error]
When set to [On], the display sends out the no signal
error.
On
5min
On
10min
On

Advertisement