2. DETAILS OF MIGRATION FROM Q17nCPUN(-T) TO RnMTCPU

2.3.2 Special relays

Device No.
Device assignment
Q17nCPUN(-T)
for M9000 to M9255
M9000/M2320
M9005/M2321
M9006/M2322
M9007/M2323
M9008/M2324
M9010/M2325
M9025/M3136
M9026/M2328
M9028/M3137
M9036/M2326
M9037/M2327
M9060/M3138
M9073/M2329
M9074/M2330
M9075/M2331
M9076/M2332
M9077/M2333
M9078/M2334
M9079/M2335
M9104/M3139
M9105/M2344
M9216/M2345
M9217/M2346
M9218/M2347
M9219/M2348
M9240/M2336
M9241/M2337
M9242/M2338
M9243/M2339
M9244/M2340
M9245/M2341
M9246/M2342
M9247/M2343
[Point]
When Q17nCPUN(-T) projects are converted into RnMTCPU projects by "file conversion", M9000 to
M9255 are automatically assigned as shown above in "Device assignment for M9000 to M9255" in
the table, however, M2320 to M3139 cannot be automatically converted.
RnMTCPU
SM2000
SM2005
SM53
SM2006
SM2007
SM2008
SM1
SM2010
SM0
SM2025
SM2026
SM2028
SM213
SM2036
SM400
SM2037
SM401
SM2060
SM50
SM2073
SM512
SM2074
SM500
SM2075
SM501
SM2076
SM502
SM2077
SM2078
SM2079
SM2104
SM2015
SM2216
SM2217
SM2218
SM2219
SM2240
SM240
SM2241
SM241
SM2242
SM242
SM2243
SM243
SM2244
SM230
SM2245
SM231
SM2246
SM232
SM2247
SM233
Name
Fuse blown detection flag
AC/DC DOWN detection flag
Battery low flag
Battery low latch flag
Self-diagnostic error flag
Diagnostic error flag
Clock data set request
Clock data error
Clock data read request
Always ON
Always OFF
Diagnostic error reset
Motion CPU WDT error flag
PCPU READY complete flag
Test mode ON flag
External forced stop input flag
Manual pulse generator axis
setting error flag
TEST mode request error flag
Servo program setting error flag
Servo parameter read request
flag
Servo parameter reading flag
No.1 CPU MULTR complete flag
No.2 CPU MULTR complete flag
No.3 CPU MULTR complete flag
No.4 CPU MULTR complete flag
No.1 CPU resetting flag
No.2 CPU resetting flag
No.3 CPU resetting flag
No.4 CPU resetting flag
No.1 CPU error flag
No.2 CPU error flag
No.3 CPU error flag
No.4 CPU error flag
2 - 23
Remarks
Not required since the Motion CPU
is battery-less.
Operated on the No.1 CPU clock
data.
The error cause is stored in SD512.
The error flag is integrated in the
self-diagnostic errors (SM0, SM1).
(Refer to section 2.2(5).)
MULTR instructions are deleted
since RnMTCPU can use CPU
buffer memory access device to
access the memory.
(Refer to section 2.2(6).)