Program Change - Boss SP-505 Owner's Manual

Boss owner's manual groove sampling workstation sp-505
Table of Contents

Advertisement

If the Pad Bank is the PITCH BANK (#15, 16), note numbers 23H (35) and 3CH-48H (60-72)
are transmitted.
Pad Number
Note Number
Pad 1
-- (--H)
Pad 2
61 (3DH)
Pad 3
63 (3FH)
Pad 4
-- (--H)
Pad 5
66 (42H)
Pad 6
68 (44H)
Pad 7
70 (46H)
Pad 8
-- (--H)
Pad 9
60 (3CH)
Pad 10
62 (3EH)
Pad 11
64 (40H)
Pad 12
65 (41H)
Pad 13
67 (43H)
Pad 14
69 (45H)
Pad 15
71 (47H)
Pad 16
72 (48H)
* Not transmitted if the Pad Bank is the CHOP BANK (#13, 14).

Program Change

Transmit the message in the MIDI channel number which is designated with "Pads
Channel" or "Part1-4 Channel" in the system parameter "SYSTEM/UTILITY/MIDI". After
the pad bank is switched, this is transmitted as a set together with note data.
This message is transmitted when the "Prog Chg SW" of the system parameter "SYSTEM/
UTILITY/MIDI" is set at ON.
Status
Second
CnH
ppH
n = MIDI Channel Number:
pp = Program Number:
+—————+———————————————+—————+———————————————+
| PC# | PAD BANK
| PC# | PAD BANK
+—————+———————————————+—————+———————————————+
|
1
| PRESET BANK 1 | 17
| CARD BANK 1
+—————+———————————————+—————+———————————————+
|
2
| PRESET BANK 2 | 18
| CARD BANK 2
+—————+———————————————+—————+———————————————+
|
3
| PRESET BANK 3 | 19
| CARD BANK 3
+—————+———————————————+—————+———————————————+
|
4
| PRESET BANK 4 | 20
| CARD BANK 4
+—————+———————————————+—————+———————————————+
|
5
| USER BANK 1
| 21
| CARD BANK 5
+—————+———————————————+—————+———————————————+
|
6
| USER BANK 2
| 22
| CARD BANK 6
+—————+———————————————+—————+———————————————+
|
7
| USER BANK 3
| 23
| CARD BANK 7
+—————+———————————————+—————+———————————————+
|
8
| USER BANK 4
| 24
| CARD BANK 8
+—————+———————————————+—————+———————————————+
|
9
| USER BANK 5
| 25
| CARD BANK 9
+—————+———————————————+—————+———————————————+
| 10
| USER BANK 6
| 26
| CARD BANK 10
+—————+———————————————+—————+———————————————+
| 11
| USER BANK 7
| 27
| CARD BANK 11
+—————+———————————————+—————+———————————————+
| 12
| USER BANK 8
| 28
| CARD BANK 12
+—————+———————————————+—————+———————————————+
| ——
| ———
| 29
| CARD BANK 13
+—————+———————————————+—————+———————————————+
| ——
| ———
| 30
| CARD BANK 14
+—————+———————————————+—————+———————————————+
| 15
| PITCH BANK 1
| 31
| CARD BANK 15
+—————+———————————————+—————+———————————————+
| 16
| PITCH BANK 2
| 32
| CARD BANK 16
+—————+———————————————+—————+———————————————+
System Common Message
This message is transmitted when the "MIDI Sync Mode" of the system parameter
"SYSTEM/UTILITY/MIDI" is set at "INT/AUTO/REMOTE".
Song Position Pointer
In Song mode, the current location is transmitted as a Song Position Pointer message when
the song is stopped.
Status
Second
F2H
mmH
nn, mm = Song Position Point: 00H 00H - 7FH 7FH
Song Select
Transmitted in one of the following operations:
When the Song mode has been selected.
When the song has been selected in the Song mode.
Status
Second
F3H
ssH
00H - 0FH (ch.1 - ch.16)
00H - 1FH (pad bank 1 - 12, 15 - 32)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Third
nnH
Chapter 15. Appendices
ss = Song Number: 00H-13H (0-19)
System Realtime Message
This message is transmitted when the "MIDI Sync Mode" of the system parameter
"SYSTEM/UTILITY/MIDI" is set at "INT/AUTO/REMOTE".
Timing Clock
Status
F8H
Start
Status
FAH
Continue
Status
FBH
Stop
Status
FCH
Active Sensing
Status
FEH
* Always transmitted at intervals of approximately 250 ms.
System Exclusive Message
Status
Data Bytes
F0H
iiH, ddH, ..., eeH
Byte
Description
F0H
Status of System Exclusive Message
ddH
Data: 00H - 7FH (0 - 127)
:
:
eeH
Data
F7H
EOX (End of System Exclusive Message)
About Model ID
The SP-505 uses 00H 39H as a Model ID.
Universal System Exclusive Message
INQUIRY MESSAGE
Identity Reply
Status
Data Bytes
F0H
7EH,10FH,06H,02H,41H,39H,01H,
00H,00H,00H,02H,00H,00H
Byte
Description
F0H
Status of System Exclusive Message
7EH
Universal System Exclusive Message Non Realtime Header
10H
Device ID
06H
General Information (sub-ID #1)
02H
Identity Reply (sub-ID #2)
41H
Manufacturer ID (Roland)
39H 01H
Device Family Code (SP-505)
00H 00H
Device family No.
00H
02H
00H 00H
Softeware Revision Level
F7H
EOX (End of System Exclusive Message)
The above Identity Reply message is transmitted when an Identity Request is received.
Status
F7H
Status
F7H
85

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents