Setup

Fill Gear Reducer Reservoir with
Oil
Open the fill cap (FC) and fill the gear reducer oil reser-
voir with 2 quarts (1.9 liters) of Graco 288414 Oil (twelve
1 quart bottles). Check the oil level in the sight glass
(SG) on the gear reducer housing. Do not overfill. See
F
. 6.
IG
NOTE: 2 quarts brings oil level above sight glass (SG)
when off, but level drops when operating.
FC
SG
F
. 6. Oil Fill
IG
3A3385B

Flush Before Using Equipment

The equipment was tested with Stoddard Solvent, which
is left in the fluid passages to protect parts. To avoid
contaminating your fluid with solvent, flush the equip-
ment with a compatible solvent or water before using the
equipment. See Flushing, page 15.