Xilinx System Generator V2.1 Reference Manual page 76

Xilinx inc. portable generator user manual
Table of Contents

Advertisement

Xilinx System Generator v2.1 Reference Guide
for k=0, 1, ... , N-1, where
is a principal N-th root of unity.
The FFT block accepts as input a stream of complex data represented as a pair of
Xilinx fixed point data and computes successive DFTs of nonoverlapping frames of N
data samples.
Block Interface
The block interface (inputs and outputs as seen on the FFT icon) are
as follows:
Input signals:
xn_r
xi_r
reset
inv
Output signals:
Xk_r
Xk_i
done
rfd
Block Parameters Dialog Box
The FFT block parameters dialog box can be invoked by double-clicking the icon in
your Simulink model.
Figure 3-50: FFT block parameters dialog box
Parameters specific to the FFT block are:
76
2
----- -
i –
W
=
e
N
real component of input data stream
imaginary component of input data stream
reset signal
0 for forward transform, 1 for inverse
real component of output data stream
imaginary component of output data stream
active high on first output sample in a frame
active high when block can accept input data
Number of Sample Points: transform length, one of 16, 64, 256, or 1024.
N