6. Use screwdriver to carefully detach spring clip from the pilot
hood.
Figure 13.d Removing the spring clip
7. Remove the pilot hood and use the 5/32" allen key to remove the
natural gas pilot orifice, and replace with propane pilot orifice.
Figure 13.e Removing the pilot hood, orifice
8. Reassemble pilot assembly and hood.
9. See regulator instructions for guide on converting the pressure
regulator gasket.
Figure 13.ee LP pressure regulator on Basic
Figure 13.eee LP pressure regulator on a Full Load
26
10. If necessary, pilot flame size can be adjusted using a flathead
screwdriver to adjust "pilADJ" screw shown
Figure 13.g Adjust pilot size
11. The manifold and inlet pressure can be verified by using a
manometer and a 1/8" rubber hose attached to the valve
ports shown here (top is manifold, bottom is inlet) Use a
soap-based leak testing solution on the valve regulator while
the unit is operating to check for any leaks
Figure 13.h Adjust pressure ports
12. Fill out required information on Propane conversion gas fitter
sign off label, attach to reverse side of rating plate. Attach
Rating plate conversion label to rating plate label. Place Valve
conversion label on valve face.