1.6

Configuration including peripheral equipment

• To prevent a malfunction, do not connect these connectors to any network other than the specified network.
• Equipment other than the servo amplifier and servo motor is optional or a recommended product.
The following is an example using MR-J5-20G-RJ.
R S T
Power supply
Molded-case
circuit breaker
(MCCB)
Magnetic
contactor
(MC)
Line noise filter
(FR-BSF01)
L1
L2
L3
Power factor
improving
DC reactor
(FR-HEL)
P+
Regenerative
option
C
*1 The power factor improving AC reactor can also be used. In this case, the power factor improving DC reactor cannot be used.
*2 This is for the MR-J5-_G-RJ servo amplifier. The MR-J5-_G servo amplifier does not have a CN2L connector. If using the MR-J5-_G-RJ
servo amplifier in a linear servo system or a fully closed loop system, connect an external encoder to this connector. Refer to the
following for the compatible external encoders.
Page 34 Parts identification
1 SPECIFICATIONS
20
1.6 Configuration including peripheral equipment
*1
P3
P4
L11
L21
CN1A
CN1B
CN6
CN8
U
CN3
V
W
CN2
CN2L
E
Controller or
servo amplifier
Controller or
servo amplifier
MR Configurator2
CN5
Analog monitor
Safety relay
Junction terminal block
*2
Servo motor
Personal
computer