Windsor Saber Compact 22 User Manual page 19

Windsor saber compact user manual
Table of Contents

Advertisement

Available languages

Available languages

Overload
Display
display
Perma-
Pcb. Störung=4
nent light
Pcb. fault=4
blinks
Bürstm.Störung=1
once
Brushmot.fault=1
Saugtb.Störung=1
Vac.mot. fault=1
Ventil.Störung=1
Valve fault=1
Fahrmt.Störung=1
Drivemot.fault=1
blinks
Bürstm.Störung=2
twice
Brushmot.fault=2
Saugtb.Störung=2
Vac.mot. fault=2
Ventli.Störung=2
Valve fault=2
Fahrmt.Störung=2
Drivemot.fault=2
blinks th-
Heiss, abkühlen!
rice
Hot, let cool!
Saugtb.Störung=3
Vac.mot. fault=3
Bürstenüberlast!
Brush Overload!
Fahrmt.Störung=3
Drivemot.fault=3
blinks four
Prüfe Battspanng
times
Check Battery!
Batteriefehler!
Battery fault!
Notaus-Schalter!
Emergency button
Errors with display
Error
Defective electronics
Short circuit in the
brush motor
Short circuit in vacu-
um motor
Short circuit in soleno-
id valve
Short circuit in drive
motor
Cable rupture in the
brush motor
Cable rupture in vacu-
um motor
Cable rupture in sole-
noid valve
Cable rupture in drive
motor
Temperature in the
electronics system is
high.
Overload vacuum mo-
tor
Overload on brush
motor
Overload drive motor
Battery voltage is not
between 17 and 33 V
Battery voltage is too
high while charging
Battery fault
Emergency-stop but-
ton has been pressed
while charging the bat-
tery.
Remedy
Call customer service.
Call customer service.
Call customer service.
Let the electronics system cool
down for at least 15 minutes.
Turn the program selection
switch to OFF or Drive. Then
select again the cleaning pro-
gram. If the fault recurs, call
customer service.
Call customer service.
Stop charging. You can still use
the machine; however, call Cu-
stomer Service
Release emergency-stop but-
ton. .