3-12. Installation configuration functions

Line
Access
I
Pre-setting
This control enables you to choose one of the 4 pre-selected installation configurations.
The hydraulic layouts for the various configurations are detailed in the section: "Installation
Configurations".
Pre-setting 1: 1 heating circuit with or without electrical back-up, with DHW tank
5700
Pre-setting 2: 2 heating circuits with or without electrical back-up, with DHW tank
Pre-setting 3: Boiler connection and 1 heating circuit and DHW tank
Pre-setting 4: Boiler connection and 2 heating circuits and DHW tank
Pre-setting 5 and more: Not used
5710
S
Heating circuit 1
S
Cooling circuit 1
5711
Set the parameter to "2-pipe system cooling" with the cooling kit.
5715
S
Heating circuit 2
S
Cooling circuit 2
5716
Set the parameter to "2-pipe system cooling" with the cooling kit. If the installation consists of 2
heating circuits.
5731
S
DHW controlling element Q3
Output electrical immersion heater
5740
S
K6
Type electrical immersion heater
5806
I
flow
5950
S
Function input H1
5953
S
Input value 1 H1
5954
S
Function value 1 H1
5955
S
Input value 2 H1
5956
S
Function value 2 H1
5960
S
Function input H3
5963
S
Input value 1 H3
5964
S
Function value 1 H3
5965
S
Input value 2 H3
5966
S
Function value 2 H3
5980
S
Function input EX1
5981
S
Contact type input EX1
5982
S
Function input EX2
5983
S
Contact type input EX2
5985
S
Contact type input EX3
6098
S
Readjustment collector sensor
6100
S
Readjustment outside sensor
6117
S
Central setpoint compensation
6120
S
Frost protection plant
6201
S
Reset sensors
6205
S
Reset to default parameters
3-12. Installation configuration functions
Function
1,2,3,... 9
Off, On
Off
4-pipe system
2-pipe system
Off, On
Off
4-pipe system cooling
2-pipe system cooling
No charging request ¦
Charging pump ¦
Diverting valve
0.1...99 kW
1: 3-stage
2: 2-stage excluding
3: 2-stage complementary
4: Modulating UX
NC (Normally-closed contact)
NO (Normally-opened contact)
NC (Normally-closed contact)
NO (Normally-opened contact)
NC (Normally-closed contact)
NO (Normally-opened contact)
-20...20°C
-3...3°C
1...100°C
On, Off
No, Yes
No, Yes
- (03-43) -
Setting range or display
Factory
setting
1
On
Off
On
Off
Diverting
valve
2
3: 2-stage
complement
ary
---
0
0
10
100
None
0
0
10
100
1
NO
Low-tariff E5
NC
NO
0°C
0°C
5°C
On
No
No
3. Function table