for heat or cool. Wait about 5 minutes for the
compressor lockout to expire. If the system is still
not running, read the cautionary statement be-
low. Then, if conditions permit, use the
buttons to move the temperature above or
below the setpoint temperature. See OPERAT-
ING YOUR THERMOSTAT.
CAUTION
!
If the outside temperature is below 50 F, DO
NOT use
or
ture above or below the setpoint tempera-
ture. Property damage may result due to
compressor slugging.
to move the tempera-
11. Why doesn't the temperature change at the
time I programmed?
There may be a number of causes for this situa-
tion. The following are primary reasons.
The EMR function is operating. The EMR
function will automatically bring on the sys-
tem automatically to bring the temperature
to the selected level by the beginning of the
or
next program period. See OPERATING
YOUR THERMOSTAT.
You have programmed the incorrect day or
time. Check your programming (be sure that
the times you programmed are correct AM
or PM times). See PROGRAMMING YOUR
THERMOSTAT.
The thermostat is in the HOLD mode. Press
RUN
to start program operation. See OP-
PRGM
ERATING YOUR THERMOSTAT.