8a. What time does the last person go to bed at
night?
b. What temperature should the house be at this
time? These will be your NHT (night) tempera-
ture settings.
Now look at the factory preprogrammed times and
temperatures shown below. If this program will suit
your needs, simply press
factory preset program.
If you want to change the preprogrammed times and
temperatures, do the following.
Heating Program for ALL days of the Week:
36
RUN
to begin running the
PRGM
PERIOD
TIME
TEMP
70
MOR
5:00 AM
70
DAY
9:00 AM
70
EVE
4:00 PM
64
NHT
10:00 PM
NOTE
To operate properly in the AUTO mode, there must
be a minimum 1 F separation between the highest
heat temperature and the lowest cool temperature
(see diagram below).
79
COOLING TEMPERATURES
78
77
76
75
HEATING TEMPERATURES
74
73
Determine the time periods and heating and cooling
temperatures for your weekday program. You must
program 4 periods for each day (MOR, DAY, EVE,
and NHT). However, you may use the same heating
Cooling Program for ALL Days of the Week:
PERIOD
TIME
MOR
5:00 AM
DAY
9:00 AM
EVE
4:00 PM
NHT
10:00 PM
DEAD BAND 1°F
TEMP
78
82
78
78

Advertisement