1. Switch position and nomenclature

Name
SW1
Metering Switch
SW2
Release Switch
SW4
Count Switch
SW5
Winding Complete Switch
SW6
Stop-down (S.D.) Switch
SW7
Self Timer Switch
SW8
Battery Check Switch
SWll Lens A-M Switch.
SW1l' Stop-down switch
SW12 Bulb switch
SW14 Timer Switch
SW15 Lamp Switch
SW16 X Sync Switch
SW16' Safety Switch
SW17 Film End Switch
SW18 2nd Curtain Switch
Canon NEW F-1 Service manual
Operation
ON: Metering activated
ON: Starts Release sequence
OFF: Shutter exposure timing starts
OFF: Winding complete
ON: Stopped-down (ganged with SWll
ON: Self timer activated
ON: Battery Check
ON: Lens set to "a" mark
OFF: Lens stopped down
OFF: "Bulb" shutter speed
ON: Timer Activated
ON: Viewfinder illumination on
ON: 1st curtain open; OFF: Winding complete
ON: Mirror up; OFF: Mirror down
ON: No film on take-up spool
OFF: When 2nd curtain starts