Download Print this page

Installation And Instructions - Mitsubishi Electric FR-A800 Plus Series Installation Manuallines

Hide thumbs Also See for FR-A800 Plus Series:

Advertisement

1 INSTALLATION AND INSTRUCTIONS

1.1 Inverter Type
Symbol
Voltage class
Symbol Structure, functionality
2
200 V class
0
4
400 V class
2
FR -
A8 0
Capacity plate
Inverter model
Serial number
*1
Models can be alternatively indicated with the inverter rated current (SLD rating).
*2
Specification differs by the type. Major differences are shown in the table below:
Type
Monitor output
FM
Terminal FM:
(terminal FM equipped
Terminal AM:
model)
CA
Terminal CA:
(terminal CA equipped
model)
Terminal AM:
*3
Conforming to IEC60721-3-3 3C2/3S2.
*4
For the FR-A820-00340(5.5K)-R2R or higher, and the FR-A840-00170(5.5K)-R2R or higher
*5
Inverter equipped with a built-in Ethernet board (FR-A8ETH).
Notes
O The rating plate shows the inverter rated current in SLD operation (Super Light Duty). The overload current rating at SLD is
110% of the rated current for 60 s and 120% for 3 s at surrounding air temperature of max. 40 °C.
O In this Instruction Manual, the inverter model name consists of the applicable motor capacity and the rated current.
(Example: FR-A842-07700(315K)-R2R)
For further specification details like capacity, current or overload current rating refer to chapter 7.
O In this installation guideline the following common designations are used for the different types of inverter models:
– FR-A8m0: Standard model
– FR-A8m2: Separated converter type
O For selecting the right frequency inverter you should know details of your application and especially the load characteristic.
O For how to read the SERIAL number, refer to page 59.
*1
Capacity
00023 to
Standard model
12120
0.4 to 500K Inverter ND rated
Separated converter type
2
-
00046
pulse train output
analog voltage output
(0 to 10 V DC)
analog current output
(0 to 20 mA DC)
analog voltage output
(0 to 10 V DC)
Description
Symbol Type
Inverter SLD rated
-1
current [A]
-2
capacity [kW]
-E1
-E2
-1
-
R2R
Rating plate
Inverter model
Input rating
Output rating
Serial number
Country of origin
Built-in EMC
Control
filter
logic
OFF
Sink logic
ON
Source logic
Communica-
Symbol Circuit board
*2
tion type
coating
FM
Without
Without
RS-485
CA
-60
*4
FM
-06
*5
Ethernet
CA
Symbol
R2R
Roll to roll dedicated model
Initial setting
Pr. 19
Rated
"Base frequency
frequency
voltage"
60 Hz
9999
(same as the power
supply voltage)
50 Hz
8888
(95% of the power supply
voltage)
Plated
*3
conductor
Without
With
Without
With
With
Function
1

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Fr-a820-00046-r2rFr-a820-00077-r2rFr-a820-00105-r2rFr-a820-00167-r2rFr-a820-00250-r2rFr-a820-00340-r2r ... Show all