Download Print this page

Specifications - Mitsubishi Electric FR-A800 Plus Series Installation Manuallines

Hide thumbs Also See for FR-A800 Plus Series:

Advertisement

7 SPECIFICATIONS

7.1 Rating
7.1.1 FR-A820 (200 V class)
Model FR-A820-m-R2R
SLD
LD
Applicable motor
*2
SND
*1
capacity [kW]
ND (initial setting)
HD
SLD
LD
Rated
*2
capacity [kVA]
SND
*4
ND (initial setting)
HD
SLD
LD
Rated current
*2
SND
[A]
ND (initial setting)
HD
SLD
LD
Overload
*2
current rating
SND
*5
ND (initial setting)
HD
*6
Rated voltage
Brake transistor
Maximum brake torque
Regenerative
braking
FR-ABR
(when the option is
used)
Rated input AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
SLD
LD
*2
SND
ND (initial setting)
HD
Rated input
*9
current [A]
SLD
LD
*2
SND
ND (initial setting)
HD
SLD
LD
*2
SND
ND (initial setting)
Power supply
HD
capacity [kVA]
SLD
*10
LD
*2
SND
ND (initial setting)
HD
*11
Protective structure (IEC 60529)
Cooling system
Approx. mass [kg]
*1
The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi Electric 4-pole standard motor.
*2
For the SND rating, the carrier frequency is always 2 kHz.
*3
The 0.2 kW motor capacity is applicable under V/F control only.
*4
The rated output capacity indicated assumes that the output voltage is 220 V for 200 V class.
*5
The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow time for the
inverter and motor to return to or below the temperatures under 100% load.
*6
The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range. However, the
maximum point of the voltage waveform at the inverter output side is the power supply voltage multiplied by about 2.
*7
Value for the built-in brake resistor
*8
Value for the ND rating
48
00046
00077
00105
00167
00250
(0.4K)
(0.75K)
(1.5K)
(2.2K)
(3.7K)
0.75
1.5
2.2
3.7
5.5
0.75
1.5
2.2
3.7
5.5
0.75
1.5
2.2
3.7
5.5
0.4
0.75
1.5
2.2
3.7
*3
0.4
0.75
1.5
2.2
0.2
1.8
2.9
4
6.4
10
1.6
2.7
3.7
5.8
8.8
1.6
2.7
3.7
5.8
8.8
1.1
1.9
3
4.2
6.7
0.6
1.1
1.9
3
4.2
4.6
7.7
10.5
16.7
25
4.2
7
9.6
15.2
23
4.2
7
9.6
15.2
23
3
5
8
11
17.5
1.5
3
5
8
11
110% of rated motor capacity for 60 s, 120% of rated motor capacity for 3 s (max. surrounding air temperature 40 °C)
120% of rated motor capacity for 60 s, 150% of rated motor capacity for 3 s (max. surrounding air temperature 50 °C)
150% of rated motor capacity for 60 s (max. surrounding air temperature 50 °C)
150% of rated motor capacity for 60 s, 200% of rated motor capacity for 3 s (max. surrounding air temperature 50 °C)
200% of rated motor capacity for 60 s, 250% of rated motor capacity for 3 s (max. surrounding air temperature 50 °C)
Three-phase 200 to 240 V
Built-in
100% torque/
*8
*7
150% torque/3%ED
*7
3%ED
150% torque/
100% torque/10%ED
10%ED
Three-phase 200 to 240 V 50 Hz/60 Hz
170 to 264 V 50 Hz/60 Hz
±5%
5.3
8.9
13.2
19.7
31.3
5
8.3
12.2
18.3
28.5
5
8.3
12.2
18.3
28.5
3.9
6.3
10.6
14.1
22.6
2.3
3.9
6.3
10.6
14.1
4.6
7.7
10.5
16.7
25
4.2
7
9.6
15.2
23
4.2
7
9.6
15.2
23
3
5
8
11
17.5
1.5
3
5
8
11
2
3.4
5
7.5
12
1.9
3.2
4.7
7
11
1.9
3.2
4.7
7
11
1.5
2.4
4
5.4
8.6
0.9
1.5
2.4
4
5.4
1.8
2.9
4
6.4
10
1.6
2.7
3.7
5.8
8.8
1.6
2.7
3.7
5.8
8.8
1.1
1.9
3
4.2
6.7
0.6
1.1
1.9
3
4.2
Enclosed type (IP20)
Self-cooling
Forced air cooling
2.0
2.2
3.4
34
3.4
00340
00490
00630
00770
00930
(5.5K)
(7.5K)
(11K)
(15K)
(18.5K)
7.5
11
15
18.5
22
7.5
11
15
18.5
22
7.5
7.5
15
18.5
22
5.5
7.5
11
15
18.5
3.7
5.5
7.5
11
15
13
19
24
29
35
12
17
22
27
32
12
14
22
27
32
9.1
13
18
23
29
6.7
9.1
13
18
23
34
49
63
77
93
31
45
58
70.5
85
31
36
58
70.5
85
24
33
46
61
76
17.5
24
33
46
61
100 % torque/
20% torque/continuous
*7
2%ED
100% torque/6%ED
45.1
62.8
80.6
96.7
115
41.6
58.2
74.8
90.9
106
41.6
49
74.8
90.9
106
33.4
44.2
60.9
80
96.3
22.6
33.4
44.2
60.9
80
34
49
63
77
93
31
45
58
70.5
85
31
36
58
70.5
85
24
33
46
61
76
17.5
24
33
46
61
17
24
31
37
44
16
22
29
35
41
16
19
29
35
41
13
17
23
30
37
8.6
13
17
23
30
13
19
24
29
35
12
17
22
27
32
12
14
22
27
32
9.1
13
18
23
29
6.7
9.1
13
18
23
6.7
6.7
8.3
15.5
15.5
01250
01540
01870
02330
03160
(22K)
(30K)
(37K)
(45K)
(55K)
30
37
45
55
75
30
37
45
55
75
22
30
45
45
55
22
30
37
45
55
18.5
22
30
37
45
48
59
71
89
120
43
53
65
81
110
39
48
65
72
99
34
44
55
67
82
29
34
44
55
67
125
154
187
233
316
114
140
170
212
288
102
126
170
190
259
90
115
145
175
215
76
90
115
145
175
FR-BU2 (Option)
151
185
221
269
316
139
178
207
255
288
130
166
207
233
304
113
150
181
216
266
96.3
113
150
181
216
125
154
187
233
316
114
140
170
212
288
102
126
170
190
259
90
115
145
175
215
76
90
115
145
175
58
70
84
103
120
53
68
79
97
110
50
63
79
89
116
43
57
69
82
101
37
43
57
69
82
48
59
71
89
120
43
53
65
81
110
39
48
65
72
99
34
44
55
67
82
29
34
44
55
67
Open type (IP00)
15.5
22
42
42
54
03800
04750
(75K)
(90K)
90/110 132
90
110
90
90
75
90
55
75
145
181
132
165
132
148
110
132
82
110
380
475
346
432
346
388
288
346
215
288
10 % torque/
continuous
380
475
346
432
346
388
288
346
215
288
380
475
346
432
346
388
288
346
215
288
145
181
132
165
132
148
110
132
82
110
145
181
132
165
132
148
110
132
82
110
74
74

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Fr-a820-00046-r2rFr-a820-00077-r2rFr-a820-00105-r2rFr-a820-00167-r2rFr-a820-00250-r2rFr-a820-00340-r2r ... Show all