WIRING
400 V class, FR-A840 (440 V input power supply, ND rating, without a power factor improving AC or DC reactor)
Applicable
Tightening
Terminal
inverter type
screw size
FR-A840-m-
*4
R2R
00023(0.4K) to
M4
00126(3.7K)
00170(5.5K)
M4
00250(7.5K)
M4
00310(11K)
M5
00380(15K)
M5
00470(18.5K)
M6
00620(22K)
M6
00770(30K)
M6
00930(37K)
M8
01160(45K)
M8
01800(55K)
M8
400 V class, FR-A840 (440 V input power supply, ND rating, with a power factor improving AC or DC reactor)
Applicable
Tightening
Terminal
inverter type
screw size
FR-A840-m-
*4
R2R
00023(0.4K) to
M4
00126(3.7K)
00170(5.5K)
M4
00250(7.5K)
M4
00310(11K)
M5
00380(15K)
M5
00470(18.5K)
M6
00620(22K)
M6
00770(30K)
M6
00930(37K)
M8
01160(45K)
M8
01800(55K)
M8
02160(75K)
M10
02600(90K)
M10
03250(110K)
M10 (M12)
03610(132K)
M10 (M12)
04320(160K)
M12 (M10)
04810(185K)
M12 (M10)
05470(220K)
M12 (M10)
06100(250K)
M12 (M10)
06830(280K)
M12 (M10)
For footnotes *1 to *4 refer to page 17.
16
Crimp terminal
Torque
R/L1,
R/L1,
[Nm]
S/L2,
U, V, W
S/L2,
T/L3
T/L3
1.5
2-4
2-4
1.5
2-4
2-4
1.5
5.5-4
5.5-4
3.5
2.5
5.5-5
5.5-5
5.5
2.5
8-5
5.5-5
4.4
14-6
8-6
14
4.4
14-6
14-6
14
4.4
22-6
22-6
22
7.8
22-8
22-8
22
7.8
38-8
38-8
38
7.8
60-8
60-8
60
Crimp terminal
Torque
R/L1,
R/L1,
[Nm]
S/L2,
U, V, W
S/L2,
T/L3
T/L3
1.5
2-4
2-4
1.5
2-4
2-4
1.5
5.5-4
5.5-4
3.5
2.5
5.5-5
5.5-5
5.5
2.5
5.5-5
5.5-5
5.5
4.4
8-6
8-6
4.4
14-6
14-6
14
4.4
22-6
22-6
22
7.8
22-8
22-8
22
7.8
38-8
38-8
38
7.8
60-8
60-8
60
14.7
60-10
60-10
60
14.7
60-10
60-10
60
14.7
80-10
80-10
80
14.7
100-10 100-10
100
24.5
150-12 150-12
125
24.5
150-12 150-12
150
46
100-12 100-12 2×100 2×100 2×100
46
100-12 100-12 2×100 2×100 2×125
46
150-12 150-12 2×125 2×125 2×125
*1
HIV, etc. [mm²]
Earthing
U, V, W P/+, P1
(grounding)
cable
2
2
2
2
2
2
3.5
3.5
3.5
3.5
3.5
5.5
5.5
5.5
8
5.5
8
5.5
8
14
8
14
22
14
22
22
14
22
22
14
38
38
22
60
60
22
*1
HIV, etc. [mm²]
Earthing
U, V, W P/+, P1
(grounding)
cable
2
2
2
2
2
2
3.5
3.5
3.5
3.5
3.5
5.5
5.5
5.5
5.5
8
5.5
8
8
14
8
14
22
14
22
22
14
22
22
14
38
38
22
60
60
22
60
60
22
60
80
22
80
80
38
100
100
38
125
150
38
150
150
38
60
60
60
Cable gauge
*2
AWG/MCM
PVC, etc. [mm²]
R/L1,
R/L1,
S/L2,
U, V, W
S/L2,
U, V, W
T/L3
T/L3
14
14
2.5
2.5
12
14
2.5
2.5
12
12
4
10
10
6
8
10
10
6
8
16
10
6
6
16
16
4
4
25
25
4
4
25
25
1
2
50
50
1/0
1/0
50
50
Cable gauge
*2
AWG/MCM
PVC, etc. [mm²]
R/L1,
R/L1,
S/L2,
U, V, W
S/L2,
U, V, W
T/L3
T/L3
14
14
2.5
2.5
12
14
2.5
2.5
12
12
4
10
10
6
10
10
6
8
8
10
10
6
6
16
16
4
4
25
25
4
4
25
25
2
2
50
50
1/0
1/0
50
50
1/0
1/0
50
50
3/0
3/0
50
50
3/0
3/0
70
70
4/0
4/0
95
95
250
250
120
120
300
300
150
150
2×4/0
2×4/0
2×95
2×95
2×4/0
2×4/0
2×95
2×95
2×250 2×250 2×120 2×120
*3
Earthing
(grounding)
cable
2.5
4
4
4
6
10
6
10
16
16
16
16
25
25
*3
Earthing
(grounding)
cable
2.5
4
4
4
6
10
6
10
16
16
16
16
25
25
25
25
35
50
70
95
95
95
120

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Fr-a820-00046-r2rFr-a820-00077-r2rFr-a820-00105-r2rFr-a820-00167-r2rFr-a820-00250-r2rFr-a820-00340-r2r ... Show all