BASIC OPERATION
Parameter Name
RT signal function
155
validity condition
selection
Stall prevention
156
operation selection
157
OL signal output timer
AM terminal function
158
selection
*16 DA1 output sign
159
selection
User group read
160
selection
Simple
Simple
Simple
Frequency setting/key
161
lock operation
selection
Automatic restart after
162
instantaneous power
failure selection
First cushion time for
163
restart
First cushion voltage
164
for restart
Stall prevention
165
operation level for
restart
Output current
166
detection signal
retention time
Output current
167
detection operation
selection
168
Parameter for manufacturer setting. Do not set.
169
170
Watt-hour meter clear
Operation hour meter
171
clear
User group registered
172
display/batch clear
User group
173
registration
174
User group clear
STF terminal function
178
selection
STR terminal function
179
selection
*14
The setting range or initial value is for standard models.
*15
The setting range or initial value is for separated converter types.
*16
The setting is available only when the FR-A8AZ is installed.
*18
The setting values "242" and "342" are available for the Ethernet models only.
32
Setting range
Initial value
0
0, 10
0
0 to 31, 100, 101
0 s
0 to 25 s, 9999
1 to 3, 5 to 14, 17,
18, 19, 21, 22, 24,
26 to 28, 30,
32 to 34, 36, 46,
1
50, 52 to 54, 61,
62, 67, 70,
81 to 84, 87 to 93,
97, 98
0
0 to 2
0
0, 1, 9999
0
0, 1, 10, 11
0
0 to 3, 10 to 13
0 s
0 to 20 s
0%
0 to 100%
0 to 400%
150%
0.1 s
0 to 10 s, 9999
0
0, 1, 10, 11
9999
0, 10, 9999
9999
0, 9999
0
9999, (0 to 16)
9999
0 to 1999, 9999
9999
0 to 1999, 9999
0 to 13, 16 to 18,
20, 23 to 28, 32,
42 to 44, 46 to 48,
50 to 53, 60, 62,
60
64 to 67, 70 to 72,
74, 81, 92, 93,
100 to 109,
111 to 117,
120 to 126, 9999
0 to 13, 16 to 18,
20, 23 to 28, 32,
42 to 44, 46 to 48,
50 to 53, 61, 62,
64 to 67, 70 to 72,
61
74, 81, 92, 93,
100 to 109,
111 to 117,
120 to 126, 9999
Parameter Name
RL terminal function
180
selection
RM terminal function
181
selection
RH terminal function
182
selection
RT terminal function
183
selection
AU terminal function
184
selection
JOG terminal function
185
selection
CS terminal function
186
selection
MRS terminal function
187
selection
STOP terminal
188
function selection
RES terminal function
189
selection
RUN terminal function
190
selection
SU terminal function
191
selection
IPF terminal function
192
selection
OL terminal function
193
selection
FU terminal function
194
selection
ABC1 terminal
195
function selection
ABC2 terminal
196
function selection
232
Multi-speed setting
to
(speeds 8 to 15)
239
Soft-PWM operation
240
selection
Analog input display
241
unit switchover
Terminal 1 added
242
compensation amount
(terminal 2)
Setting range
Initial value
0
1
2
3
0 to 13, 16 to 18,
20, 23 to 28, 32,
42 to 44, 46 to 48,
4
50 to 53,
62, 64 to 67,
70 to 72, 74, 81,
5
92, 93,
100 to 109,
111 to 117,
6
120 to 126, 9999
*14
24
*15
10
25
62
0 to 8, 10 to 16,
0
25, 26, 30 to 35,
39 to 48, 55, 64,
67, 68, 79, 80, 85,
1
90 to 99,
100 to 108,
*14
2
110 to 116, 125,
126, 130 to 135,
*15
9999
139 to 148, 155,
164, 167, 168,
3
179, 180, 185,
190 to 199,
206 to 208,
211 to 213,
231 to 239, 242,
4
306 to 308,
311 to 313,
331 to 339, 342,
*18
9999
0 to 8, 10 to 16,
25, 26, 30 to 35,
39 to 48, 55, 64,
67, 68, 79, 80, 85,
99
90, 91, 94 to 99,
100 to 108,
110 to 116, 125,
126, 130 to 135,
139 to 148, 155,
164, 167, 168,
179, 180, 185,
190, 191,
194 to 199,
206 to 208,
211 to 213,
9999
231 to 239, 242,
306 to 308,
311 to 313,
331 to 339, 342,
*18
9999
9999
0 to 590 Hz, 9999
1
0, 1
0
0, 1
0 to 100%
100%