Electrical; Electrical Connections - InSinkErator SS-50 Installation, Care & Use Manual

Commercial disposer
Hide thumbs Also See for SS-50:
Table of Contents

Advertisement

WARNING
Electrical Shock
• Turn off the electrical supply to the disposer before serv-
icing. Test the circuit with a volt meter or circuit tester to
ensure the power is off.
• All control centers and disposers must be grounded.
• A properly fused disposer control (with a marked "off"
position) that disconnects all ungrounded supply conduc-
tors must be installed at the electrical supply source.
Personal Injury/Property Damage
If the electrical installer is not experienced in electrical
installation, we recommend seeking competent professional
assistance. Disposer or accessory damage due to improper
installation is not covered under warranty. All installations
must comply with local electrical codes.
Property Damage
• Disposers shipped from the factory are not wired for a
specific voltage. Refer to the motor connection wiring
diagram in the terminal box for voltage instructions.
• Ensure the disposer motor voltage and phase match that
of the electrical supply.
Disposer Controls
Install the disposer controls within sight of the disposer (per local codes) so the disposer can be reached easily in an
emergency situation. In-Sink-Erator approved disposer/control combinations are listed in Table 3.
Model
Phase
SS-50
1
SS-50
3
SS-75
1
SS-75
3
SS-100
1
SS-100
3
SS-125
1
SS125
3
SS150
1
SS-150
3
SS-200
1
SS-200
3
SS-300
3
SS-500
3
SS-750
3
SS-1000
3
X= Approved
0= Not Available

Electrical

Manual
Manual
Start Switch Reverse Switch Starter Switch
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
O
X
O
X
O
O
O
O
Table 3: Disposer/Control Combinations

Electrical Connections

To connect the disposer to the electricity:
1. Remove the screw in the center of the disposer terminal
box.
2. Pull the terminal box out of the stainless-steel trim shell.
3. Connect an electrical conduit connector to the hole in the
bottom of the exposed wiring compartment.
4. Connect the ground wire to the ground screw.
5. Connect the incoming wires to the motor leads. Make
sure the wiring connections are the same as those on the
motor control wiring diagram for your specific control
(see pages 10 - 16).
6. Reinstall the terminal box cover on the trim shell.
WARNING
Electrical Shock
Be careful not to pinch or damage the electrical wires
when installing the terminal box.
NOTE: Complete electrical information is located inside the
disposer terminal box.
7. Test the disposer to ensure the cutting elements revolve
and the water flows automatically. Make sure the
disposer is securely mounted and does not leak from any
of the connections.
Magnetic
CC202
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
O
X
O
X
7
CC101
AS101
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents