Electrical Connections

These electrical diagrams are recommended for the most commonly used accessory combinations. Wiring diagrams for the
MSLV, CC202, CC101, and AS101 are supplied with the product.
NOTES: • All electrical connections must comply with local electrical codes.
• Pressure switches may be connected across the line at 5 horsepower or less. Larger horsepower motors require
connection in the pilot circuit of a magnetic starter.
• The magnetic and manual starters supplied by In-Sink-Erator do not require heaters to complete the circuit.
In-Sink-Erator disposers are equipped with overload protectors.
• A time delay may only be used with a water solenoid valve.
DANGER
Electrical Shock
• Turn off all electrical supply to the disposer before attempt-
ing any work on it. Use a voltmeter or circuit tester to
ensure power is off.
• Installation must conform to all local electrical codes.
• All control centers and disposers must be carefully and
permanently grounded.
• A properly fused disconnect must be installed at the electri-
cal supply source for the control center.
Disposer Motor Wiring
Start
Switch

Wiring Diagrams

Overload
Protector
Property Damage
• Ensure that the control center voltage and phase match
the disposer motor and electrical supply. Check name-
plates on disposers and control centers for voltage and
phase specification.
• The disposer motor wiring connection is shown in the
disposer terminal box.