Operation; Pressure Relief Procedure; Cleaning Solutions - Graco Hydra-clean 24V616 Instructions - Parts Manual

Hydraulic packages
Table of Contents

Advertisement

Operation

Operation
Operation
Operation
To reduce the risk of overpressurizing your system,
which could cause component rupture and serious
injury, follow these precautions:
• Never exceed 1900 psi (13.1 MPa, 131 bar)
hydraulic input to the motor.
• Never exceed the maximum fluid working
pressure of 3000 psi (20.7 MPa, 207 bar) for
low-pressure models or 4300 psi (29.6 MPa,
296 bar) for high-pressure models.
• When starting the hydraulic system, open the
return line shutoff valve (N) first, then open the
hydraulic supply line valve (M).
Pressure Relief
Relief Procedure
Procedure
Pressure
Pressure
Relief
Procedure
Follow the Pressure Relief Procedure
whenever you see this symbol.
This equipment stays pressurized until pressure is
relieved manually. To help prevent serious injury
from moving parts or from pressurized fluid, such
as skin injection or splashing in the eyes or on
skin, follow the Pressure Relief Procedure when
you stop pumping and before you clean, check, or
service the equipment.
12
1. Engage the gun trigger lock.
2. Close the hydraulic supply shutoff valve (M).
3. Disengage the gun trigger lock.
4. Hold a metal part of the gun firmly to the side of a
grounded metal pail. Trigger to relieve pressure.
5. If you suspect the spray tip or hose is clogged or
that pressure has not been fully relieved:
a. VERY SLOWLY loosen the hose end
coupling to relieve pressure gradually.
b. Loosen the coupling completely.
c. Clear hose or tip obstruction.
6. When all pressure is relieved, close the hydraulic
return shutoff valve (N).

Cleaning Solutions

Cleaning
Cleaning
Solutions
Solutions
Cleaning chemicals may be toxic. To avoid serious
irritation to your eyes or skin, wear appropriate
protective clothing, such as waterproof outerwear
and eye goggles, according to the cleaner
manufacturer's recommendations.
1. Prepare the cleaning solution according to the
manufacturer's instructions.
2. If you are using powdered cleaners, mix them
thoroughly in a separate pail before adding them
to a supply drum.
NOTICE
NOTICE
NOTICE
Undissolved powders are extremely abrasive and
may damage pump parts. Mix powdered cleaners
thoroughly.
334187H

Advertisement

Table of Contents
loading

Table of Contents